康佳彩电工厂调试,S(SN)系列彩电电视调试说明(新)(国外英文资料)
康佳彩电工厂调试,S(SN)系列彩电电视调试说明(新)(国外英文资料)
One, foreword
Scope of application
This debug specification applies to the S (SN) series color TV sets.
Debugging considerations and requirements
(1) please click the following debugging steps and the specified test equipment debugging, otherwise will not be able to set the TV, in order to ensure satisfactory test results, shall be guaranteed by a bias value specified in the debugging.
(2) to debug the movement of the installed memory N104, must advance with the writer before installation will be the mother of data to them, and without design personnel permits may not change this debug instructions listed in the debug data outside of the project.
Before debugging, the machine must be pre-heated for 30 minutes, and the whole machine should be demagnetizing.
Second, the debugging environment
Temperature: 15 to 35 degrees Celsius
2, the relative temperature is 45 to 75%
3, 86-106 kpa
Test instruments (the following instruments must be calibrated)
1, voltmeter,
2, the oscilloscope
3, multimeter (20 k Ω resistance: DC or AC acuity Ω 5 k/V/V)
High pressure table 40KV
5, degaussing coil
Philip image generator (HH5818)
4, debug project and debug method
Middle frequency debugging.
1) break the IF end of the high frequency head.
2) enter the 8V stabilizer in the N906 (7805) input and 12V stabilizer at N904 (7809).
3) enter the signal generator (PH5518) into the IF input (R101 and C101 common points), and enter the 38.0 MHZ and other signal 95dB.
4) the oscilloscope or digital voltmeter is connected to the Pin8 foot of the N103, the negative grounding, the adjustment of the medium frequency oscillation (t10s), the adjustment of the voltmeter is 1.60 V plus or minus 0.05 V. (the core is in midweek)
High frequency ACG adjustment
1) a receiving signal (U channel).
2) set up a grey scale signal of 53dB mu V on a regular basis.
3) adjust RP120 to make the C119 positive just 4.0 V plus or minus 0.1 V.
3, the factory adjust the use method of the te