微流控非接触电导检测芯片的设计与模拟(国外英文资料).doc

微流控非接触电导检测芯片的设计与模拟(国外英文资料).doc

  1. 1、本文档共29页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
微流控非接触电导检测芯片的设计与模拟(国外英文资料)

微流控非接触电导检测芯片的设计与模拟(国外英文资料) Her collection of Feel very useful So upload to baidu Share it with you! The design and simulation of microfluidic non-contact conductive test chip Zhao Ping 1 Chong-gang fu 1 * Wang lixin 2 (1) the college of chemistry at the university of liaocheng university Liaocheng 252059; Liaocheng university media and technology institute Liaocheng 252059). Abstract: microchip non-contact electrical conductivity detection system is made by microprocessing technology The influence of excitation voltage, excitation frequency and concentration on output signal was investigated The simulation circuit of the detection pool was simulated by wewb5.0 software By comparing experiments and simulation results It is found that the two have good consistency It is indicated that the analog circuit is a better reflection of the electrical characteristics of the non-contact detector Keywords: microfluidic chips; Non-contact conductivity detection pool; Equivalent circuit simulation Middle image classification number: O657. 8 document identification code: A post number: The Design and simulation of Microfluidic chip with contactless conductivity detection ZHAO Ping1, FU chong-gang1 *, WANG li-xin2 (1) the School of chem. China; 2 School of Media and Communication Technology, Liaocheng University, Liaocheng, 252059, China Abstract:A microchip system with contactless conductivity detection (CCD) was manufactured by micro-fabricating technology. A variety of factors affecting output signals such as excitation voltage, excitation frequency and solution concentrations were investigated. The equivalent circuit of the CCD detection cell was simulated using wewb5.0 software. It was found that the experimental and simulation results were in good agreement. The equivalent circuit well represented the electrical characteristics of CCD cell Keywords: Microfluidic chip; Contactless conductivity detection cell; Equivalent circuit simulation Deadline: 2011-05-10 Fund project: nat

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档