新时达F参数说明(国外英文资料).docVIP

  1. 1、本文档共10页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
新时达F参数说明(国外英文资料)

新时达F参数说明(国外英文资料) Mainboard parameter specification (with no parameter classification operator) Parameter parameter meaning note the factory value unit read The acceleration of the slope adjustment is 550 mm/s2 0.55 m/s2 The slope of the deceleration is adjusted to the speed of the brake by 550 mm/s2 0.55 m/s2 The 2s curve T0 starts at the beginning of S curve at 1300 0.01 S 1.300 S The 3 S curve T1 is accelerating to the end of S curve at 1100 S 1.100 S The 4 S curve T2 decelerates at the beginning of S bend at 11000.01 S 1.100 S The S curve T3 deceleration S curve time 130.01 S 1.300 S The elevator rating of the elevator is 1750mm/s 1.75 m/s The rating of the motor rated speed motor is 1450rpm 1450rpm The pulse count of the encoder was 1024 PPR 1024ppr after the PPG The base station that is returned when the ladder is locked The solid layer is 0 The total number of plugboards installed in the total number of Wells is 18 The speed of service is 250 mm/s 0.250 m/s The speed of the return flat is 60 mm/s 0.060 m/s The door closes at 30 0.1 s The door will be open for 30 0.1 s The 16-gate delay is given by the governor running signal to begin the delay time of the opening and opening of the brake. 2 0.1 s, 0.2 s Removal of the running delay from the start of the lock to the removal of the governors signal from the delay time of 60.1 s 0.6 s Station 1 when fire station fire station fire status No.2 fire station 1 Delay return base time 0: no delay, return to base station immediately. 0 s 0 s The 21 flat layer error is the adjustment of the single layer of elevator and the flat layer error of the multi-layer operation The primary base station in parallel is the first base station in parallel (see F20, F196, F197) 1 In parallel mode 1: parallel ladder (compatible with old procedure) 2: group control (compatible with older programs) (see F181) 3 Driver mode 0: digital quantity; 1: analog 1 Type 1 X0 -x15, often open or close to 481 Type 2 x16-x31 input points often open o

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档