GREE KFR--50L/H610 fault code
E1: the compressor current is too large, the compressor overheating, high exhaust temperature, module protection, should check whether the overload protector is broken and the compressor temperature sensitive package is short circuited.
E2: antifreeze protection for indoor evaporators.
E3: room temperature, temperature head, short circuit or open circuit.
E4: indoor evaporator pipe temperature sensitive head short circuit or open circuit.
E5: indoor and outdoor communication failure.
GREE inverter fault display table
LED1, LED2, LED3, D1, D2, D3, malfunction
Green light, compressor operation
Yellow light, outdoor environment, temperature package failure
Red light, outdoor pipe temperature sensitive bag is faulty
Flashing module protection
Overload protection of flashing flashing compressor
Green light, red light, yellow light, exhaust temperature, package failure
Operation of bright compressor
Blinking communication works normally, otherwise it is not normal
There is a malfunction in the temperature sensor inside the flashing room
LED1, LED2 and LED3 are outdoor fault display lights; D1, D2 and D3 are indoor display lights
(in which the outdoor machine fault indication is indicated only when the compressor stops running)
GREE E1 troubleshooting
First of all, to determine whether the air conditioner is running for some time, failure or boot failure, to distinguish between system failure or circuit fault, the main aspects of the system:
1 emptying is not clean / new machine
2 excessive injection / repair
3 external machine
High temperature / poor ventilation? Dirty block? The environment is bad
Circuit: short circuit board in OVC and the zero line, such as to failure, the board / bad repair, change, if not failure, check whether the high-voltage switch turn-on switch should be conducted under atmospheric pressure , such as check, high voltage switch and OVC connection, such as barrier, repair of high-voltage sw
您可能关注的文档
最近下载
- 人教PEP版六年级上册Unit 5 What does he do 单元整体教学设计.pdf
- 2021年新生儿感染:抗菌药物预防性与治疗性使用指南解读(全文).pdf
- 《数字图像处理教程》试题库.pdf VIP
- 学校意识形态工作计划.pdf
- 战略模拟软件CESIM全攻略(课堂PPT).ppt
- 中国碳交易政策对可持续经济福利的影响.pptx VIP
- 反三违(典型“三违”)行为清单.docx
- (高清版)B-T 3836.1-2021 爆炸性环境 第1部分:设备 通用要求.pdf VIP
- 人教版高一化学必修一知识点梳理.docx
- 人教pep版英语三年级上册阅读理解专项复习试卷测试题(含答案).doc
文档评论(0)