GREE 格力空调 故障代码(国外英语资料).doc

GREE 格力空调 故障代码(国外英语资料).doc

  1. 1、本文档共10页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
GREE 格力空调 故障代码(国外英语资料)

GREE 格力空调 故障代码(国外英语资料) GREE KFR--50L/H610 fault code E1: the compressor current is too large, the compressor overheating, high exhaust temperature, module protection, should check whether the overload protector is broken and the compressor temperature sensitive package is short circuited. E2: antifreeze protection for indoor evaporators. E3: room temperature, temperature head, short circuit or open circuit. E4: indoor evaporator pipe temperature sensitive head short circuit or open circuit. E5: indoor and outdoor communication failure. GREE inverter fault display table LED1, LED2, LED3, D1, D2, D3, malfunction Green light, compressor operation Yellow light, outdoor environment, temperature package failure Red light, outdoor pipe temperature sensitive bag is faulty Flashing module protection Overload protection of flashing flashing compressor Green light, red light, yellow light, exhaust temperature, package failure Operation of bright compressor Blinking communication works normally, otherwise it is not normal There is a malfunction in the temperature sensor inside the flashing room LED1, LED2 and LED3 are outdoor fault display lights; D1, D2 and D3 are indoor display lights (in which the outdoor machine fault indication is indicated only when the compressor stops running) GREE E1 troubleshooting First of all, to determine whether the air conditioner is running for some time, failure or boot failure, to distinguish between system failure or circuit fault, the main aspects of the system: 1 emptying is not clean / new machine 2 excessive injection / repair 3 external machine High temperature / poor ventilation? Dirty block? The environment is bad Circuit: short circuit board in OVC and the zero line, such as to failure, the board / bad repair, change, if not failure, check whether the high-voltage switch turn-on switch should be conducted under atmospheric pressure , such as check, high voltage switch and OVC connection, such as barrier, repair of high-voltage sw

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档