短肢剪力墙的配箍绿(国外英文资料).docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
短肢剪力墙的配箍绿(国外英文资料)

短肢剪力墙的配箍绿(国外英文资料) The reinforcement problem of short leg shear wall structure in non seismic area is discussed Non seismic zone 15 storey short shear wall structure reinforcement, all the longitudinal reinforcement of short pier shear wall section rate according to the number and structure design for? How to configure the edge members of stirrup stirrup ratio, to meet the requirements? 1. non seismic area 15 layer short leg shear wall structure, all longitudinal reinforcement ratio is best to take 1%, 2. the volume ratio of stirrups of the edge component satisfies the minimum volume, the reinforcement ratio is good, that is to say, the stirrup characteristic value is v 0.1 Hoop green of short limb shear wall According to the diagram given in the current specification, the use of stirrups is only specified in the shadow areas, rather than by drawing tendons, The reinforcement shall be included in the stirrup volume and stirrup ratio. However, many designers consider pulling the tendons into the volume ratio, The reason is similar composite stirrups, and the columns of the columns are not aimed at shear resistance. To do so, in the steel bar There will be a certain amount of savings. Wall to column stirrups in general high-rise buildings are more common with D12@100, of course Well, after the new specification, it can basically meet the requirements of volume stirrup ratio, so the reinforcing bars in the constraint component are required Configuration can also be configured. But in some cases, for example, if a steel bar is to be used as a stirrup, it may be simply sealed The closed stirrups are difficult to satisfy. Whether horizontal reinforcement can be included in stirrup volume and stirrup ratio is debated continuously. I dont think thats relevant to the specification Technical explanations are directly related, or further, the norm should be responsible for this. Because the specification itself is not clear Make sure that the shear wall sets up the wall column

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档