市政类二级建筑师模拟题(国外英语)
市政类二级建筑师模拟题(国外英语资料)
(a)
The structure of the road structure is: 7cm asphalt concrete pavement, 15cm thick cement stable gravel, 15cm thick and 12% lime stable soil, 15cm thick and 8 per cent lime improve soil cushion layer. The excavation depth is within 0.2 ~ 1m. The construction period is during the rain period.
According to the scene (1), answer the following questions:
The appropriate way to do this is ().
A must be excavated according to the center line of the measuring and the side pile, and the average length of each side is 300 ~ 500mm
B: no, no, no, no, no, no, no
The C roller is not less than 8t roller
D cross street rainwater pipe should be run after roller compaction
Answer: A,
In the compaction of the subsoil compaction, the soil moisture content reaches () the compacted effect is the best.
A liquidity limit
B the best water content
C saturation water content
D plastic limit
Answer: B
3, the mud stabilizes the gravel from start to add water to completely compacted delay time, usually not exceed ()
A3h
B5h
C6h
D3 ~ 4 h.
Answer: D
When the engineering surface layer is pressed, it is strictly forbidden to brush or spray () on the wheel.
A mixed detergent water
B diesel
C isolation agent
D anti-sticking agent
Answer: B
In the column option, the measures for the construction of the road base rain are ()
A day is finished, finished, compacted, left behind
B how much, how much, how much, how much
C does not allow the construction of the lower layer wet, in time to spread out and finish the compaction
D build a movable tent at the site so that it can continue when it rains
Answer: A,
(2)
The construction of a municipal overpass project is based on the cast-in-place pile, the eight prismatic pier, and the upper structure is the prestressed concrete box girder with the cross-diameter 25m. The pile foundation is mainly through gravel soil (less than 20% gravel, which is more than two-thirds of the diameter of the drill pipe). The project is subcontracted to the pr
您可能关注的文档
- 八年级下(国外英文).doc
- 八种辣椒酱的制作方法(国外英文).doc
- 公共关系(国外英语).doc
- 公共关系学-在线作业_A(国外英文).doc
- 公共关系2-1(国外英文).doc
- 八年级上科学作业本答案(国外英文).doc
- 公共厨房的通风设计(国外英文).doc
- 公共基础常识积累精华练习(国外英语).doc
- 公函书写(国外英文).doc
- 公务员专业分类(重要)(国外英文).doc
- GB/T 30290.4-2025北斗卫星定位车辆信息服务系统 第4部分:车载信息终端性能要求及测试方法.pdf
- 《GB/T 30290.4-2025北斗卫星定位车辆信息服务系统 第4部分:车载信息终端性能要求及测试方法》.pdf
- GB/T 30290.2-2025北斗卫星定位车辆信息服务系统 第2部分:车载终端与服务中心信息交换协议.pdf
- 《GB/T 30290.1-2025北斗卫星定位车辆信息服务系统 第1部分:功能描述》.pdf
- GB/T 30290.1-2025北斗卫星定位车辆信息服务系统 第1部分:功能描述.pdf
- 中国国家标准 GB/T 30290.1-2025北斗卫星定位车辆信息服务系统 第1部分:功能描述.pdf
- 中国国家标准 GB/T 30290.2-2025北斗卫星定位车辆信息服务系统 第2部分:车载终端与服务中心信息交换协议.pdf
- 《GB/T 30290.2-2025北斗卫星定位车辆信息服务系统 第2部分:车载终端与服务中心信息交换协议》.pdf
- 中国国家标准 GB/T 31840.2-2025额定电压1 kV(Um=1.2 kV)到35 kV(Um=40.5 kV)铝合金芯挤包绝缘电力电缆 第2部分:额定电压6 kV(Um=7.2 kV)到30 kV(Um=36 kV)电缆.pdf
- 《GB/T 31840.2-2025额定电压1 kV(Um=1.2 kV)到35 kV(Um=40.5 kV)铝合金芯挤包绝缘电力电缆 第2部分:额定电压6 kV(Um=7.2 kV)到30 kV(Um=36 kV)电缆》.pdf
原创力文档


文档评论(0)