(万科)住宅设计统一技术措施(建筑)(Unified technical measures for residential design (construction)).doc

(万科)住宅设计统一技术措施(建筑)(Unified technical measures for residential design (construction)).doc

  1. 1、本文档共23页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
(万科)住宅设计统一技术措施(建筑)(Unified technical measures for residential design (construction))

(万科)住宅设计统一技术措施(建筑)(Unified technical measures for residential design (construction)) Unified technical measures for residential design (1) November 21, 2007 1. General graphic design 1. The distance between 1.1 the h value (net size) should not be greater than 2.4 m when the building plane is misaligned, so as not to affect the lighting. 2. The fire 2.1 in the general plan, the fire lane and fire engines should be designed with high design. When the fire lane is below the basement, the structure should consider the total weight of fire trucks at 300KN. 2.2 high surface 2.2.1 the upper surface shall be settled within the red line of the land, and the green belt shall be used to make a high surface in the condition of the condition, but the green belt shall be set hard and shall be calculated according to the total weight of the fire engine. 2.2.2 when the concave entry of the building is not more than 4m (net width), the concave entry can be counted as the height of the surrounding area. If the groove width is not greater than 2.5 m (net width), the width is not included in the overall length of the building. 2.3 fire lane 2.3.1 the fire lane is set up around the high-rise buildings and two long edges of the building; The full end of the fire lane should be 18m x 18m back. 2.3.2 the minimum turning radius of the fire truck: 12m at the top and 9m in the upper layer. 2.3.3 minimum width of fire lane: 6m at height and 4m elsewhere. 2.3.4 fire lanes slope: ≯ 1%, other ≯ 7%. 2.3.5 the fire lane distance from the building is suitable for 5m. 2.3.6 if the length of the high-rise building is more than 150m or the total length exceeds 220m, it shall be set through the fire channel of the high-rise building. 2.3.7 high-rise buildings should be equipped with a pedestrian passageway connecting streets and inner courtyard. The distance between the channels should not be more than 80m. 3. Streamline design The entrance of the residence shall be set up for the use of the special ch

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档