扬子空调故障代码(The fault code of the Yangtze air conditioner)
扬子空调故障代码(The fault code of the Yangtze air conditioner)
KFR - 23 gw (D),
KFR - 32 gw/C (D)
Fault code failure indication
Temperature sensor fault timing lights flashing
Tube temperature sensor failure sleep light flashing
System breakdown defrost lamp flicker
45 lw KF (R) - (/ D)
E1 high voltage protection disconnect
E2 prevents high load protection
E3 prevents freeze protection
E4 system exception protection
E6 indoor temperature sensor is damaged
E7 indoor coil temperature sensor is damaged
Fault code failure indication
-kf (R) -48lw/A (D).
- KF (R) - 50LW (/ AD).
- KFR - 60 / AD.
- KFR - 70 lw/C (D)
-kf (R) -- 120LW (/ BD)
Fault code failure indication
- E1 high voltage protection disconnect
- E2 prevents high load protection
- E3 prevents freeze protection
- E4 system exception protection
- E6 indoor temperature sensor is damaged
- E7 indoor coil temperature sensor is damaged
Ordinary split machine, 1: the E1 with the light box is shown to stop immediately, except that the light box can be opened and other functions are useless. [simple solution: the control panel of the OVC line and zero line short sub, is still the E1 for panel bad, dont show the E1 is that high pressure protection switch, disconnect] 2: E3 fault some machine doesnt have a low voltage protection switch, but in all control components also is cannot solve the problem, it is now a lot of control panel is common, as long as the LPP line and zero line in the control panel nipple is ok!
Iii. Maintenance information of variable frequency air-conditioning
1. Exhaust temperature protection: when T exhaust is above 115 degrees, the compressor stops, less than 90 degree press stops and the operation is resumed after three minutes.
2. Anti-freeze protection: when the inner tube is less than -1 degree, the compressor stops and the compressor stops for three minutes.
3 over-current protection: when the I is always greater than D, the compressor stops and the external fan is delayed for 30 seconds
32 machin
您可能关注的文档
- 工程经济课后答案(After-school answers to engineering economics).doc
- 工程经济6(Engineering economy 6).doc
- 工程测量试卷A卷期末试题(Project A book A final exam).doc
- 工程结构脆性断裂事故分析(Analysis of brittle fracture accident of engineering structure).doc
- 工程结构(Engineering structure).doc
- 工程规划~城市设计道路管网~(Project planning ~ urban design road network).doc
- 工程财务管理(Engineering financial management).doc
- 工程项目管理选择判断(Project management selection judgment).doc
- 工艺学复习(Process review).doc
- 工程项目管理法(Engineering project management).doc
文档评论(0)