网站大量收购独家精品文档,联系QQ:2885784924

汽油存放(Gas storage).doc

  1. 1、本文档共10页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
汽油存放(Gas storage)

汽油存放(Gas storage) Discussion: gasoline storage 120 # solvent for gasoline storage and use of site fire prevention requirements 120 # solvent gasoline, also called rubber industrial solvent gasoline, referred to as rubber solvent oil, main ingredients for fat hydrocarbons, colorless transparent liquid, density is not greater than 0.730, the range of 80-120 ℃, ignition temperature: 415 ℃, flash point: 30 ℃, explosion limit (V/V) : 1.3% - 6%, the fire hazard: b. Acute toxicity rating: low toxicity. One, 120 # solvent gasoline use site requirements 1. The fire resistance level of the rubber workshop should not be lower than the secondary level, which is less than 300 m2 of the single-storey buildings, and the fire resistance rating should not be lower than the third level; The door for evacuation of the workshop should be opened in the direction of evacuation and open the door. 2, secondary refractory grade glue factory with other building of fireproof rank second workshop and warehouse under (b) fire separation between not less than 10 meters, if less than 10 meters, must use a firewall; The rubber workshop must be equipped with explosion-proof axial flow fan; According to the characteristics of the operation, the ventilation measures such as forced exhaust and positive pressure air supply are set up. 4. The electrical facilities in the explosion-proof area of the rubber workshop must be explosion-proof, and the electric wires shall be protected by galvanized pipe. It is forbidden to bring non-explosion-proof electrical appliances (such as mobile phones and non-explosion-proof lamps) into the workshop. 5. Fixed combustible gas alarm must be installed inside the workshop. The maximum protection distance in the room is 7.5m, and 24h is guaranteed to be monitored and assigned to be on duty. 6. The fire spacing between the glue workshop and the civil building should not be less than 25m, and the fireproof distance of important public buildings should not be less than 50

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档