混凝土计算(Concrete calculation)
混凝土计算(Concrete calculation)
1. The design value of the axial force is 2650kN and the calculation length is calculated. H = 3.6 m, the concrete strength level is C30 (fc = 14.3 N/mm2), the steel bar HRB400 (fc = 14.3 N/mm2), the environment category is one class. Determine the size and area of the column area.
Solution: according to the construction requirement, the section size of the column is assumed to be 400mm by 400mm
By ι. / b = 3600/400 = 9, which is psi = 0.99
As = 1 / fy (N / 0.9 bits of fcA) = 1906 was
Rho = As/A x400 = 1906/400 = 1.2% rho min = 0.6%
For each side of the symmetrical reinforcement section, the reinforcement rate also meets the structural requirements of 0.2%.
Choose 4 Φ 25, As = 1964 was
The design area and the calculated area error (1964-1906) / 1906 = 3% 5%, meet the requirements.
2. The structure of a multilayer cast-in-site frame plant standard layer of column, axial pressure design value N = 2100 kn, floor high H = 5.60 m, length calculation l0 = 1.25 H, in C30 concrete (fc = 14.3 N/was), reinforced by the level of HRB335 (fc = 300 N/was), environment for categories. Determine the section size and longitudinal area of the column.
According to the construction requirements, the section size of the column is assumed to be 400mm by 400mm
The length is thinner than the air. B is equal to 17.5, and the table of psi is 0.825
According to the formula of the axial compression bearing capacity, As = 1 / fy (N / 0.9 psi - fcA) = 1801mm2, rho = As/A = 1.1% rho min = 0.6%, and the ratio of each side of the symmetrical reinforcement section meets the structural requirements of 0.2%.
Choose 6 Φ 20, As = 1884 was
The design area and calculation area error 1884-1801/1801 = 4.6% 5%, meet the requirements.
3. At the bottom of the structure of the cast-in-place cast-in-place structure, the length of the column is calculated. = 4.2 m, cross section size is 300 mm * 300 mm, the column is equipped with 4 Φ 16 longitudinal reinforcement (fc = 300 N/was),
您可能关注的文档
- 构建和谐工地 推动项目管理(Build a harmonious site to promote project management).doc
- 林业技术毕业论文(Graduation thesis on forestry technology).doc
- 果树嫁接改良技术要点(The key points of grafting improvement of fruit trees).doc
- 果树栽培(Fruit cultivation).doc
- 果树营养的年周期分配规律(The annual cycle distribution of fruit tree nutrition).doc
- 枣庄通病防治(Prevention and cure of disease in zaozhuang).doc
- 架空线路中导线架设施工工艺(Construction process of wire in overhead line).doc
- 架线安全技术交底(The security technology of the wire line).doc
- 枸杞对小白鼠免疫功能影响(Effects of lycium on immune function in mice).doc
- 某学院新校区校园网规划与设计(Plan and design of campus network of a new college campus).doc
文档评论(0)