负荷计算公式(Load calculation formula)
负荷计算公式(Load calculation formula)
Calculation formula of air conditioning cooling load
Calculation formula for heat transfer of external wall and roof heat transfer
Cooling load Q tau (W) is calculated at the calculated time of the formation of external wall or roof heat transfer.
Q tau tau = k. f. Δ t - factor (1.1)
Type:
F - computing area, ㎡;
Tao -- computing time, o clock;
The time when the temperature wave ACTS on the outer wall or the outside of the roof.
Δ t tau - function factor - moment, through the wall or roofing cooling load calculation of the temperature difference, referred to as load temperature difference, ℃.
Note: for the outer walls of the delay time is 5 hours, for example, in room 16 points to determine the cooling load of the heat transfer, the computing time to tau = 16, time delay factor = 5, part time for tau factor = 16-5 = 11. This is because the cooling load on the surface of the 16-hour external wall due to temperature fluctuation is the result of the temperature fluctuation outside the external wall at 5 hours.
When the attenuation coefficient of the outer wall or the roof is beta 0.2, the daily average cold load Qpj can be used instead of the cold load Q tau of each calculation moment:
Qpj = k. f. Δ TPJ (1.2)
Type:
Δ TPJ - load average daily temperature difference, ℃.
The temperature difference of the outside window is hot and cold
The calculation of cold load Q tau is calculated according to the calculation of the calculation of heat transfer in the external window.
Q tau tau = a. k. f. Δ t (2.1)
Type:
Δ t tau - calculating moment under the temperature load, ℃;
K - heat transfer coefficient;
A - window frame correction factor.
External window solar radiation cooling load
The calculation of the cooling load Q tau at the time of solar radiation from the outer window shall be calculated according to the following categories according to different conditions:
When the outer window has no shading facilities
Q Jw tau tau = F, Xg, (3.1)
Typ
您可能关注的文档
- 脑梗宜忌(Avoid cerebral infarction was appropriate).doc
- 脚手架工程标识要求(Requirements for the identification of scaffolds).doc
- 脚手架搭设规范施工方案(Scaffolds shall set up a standard construction plan).doc
- 脚手架施工方案(Scaffolding construction scheme).doc
- 脚本命令大全(Script commands are complete).doc
- 脱扣特性如何选(How to choose the trip feature).doc
- 脱离操作系统的bootloader—44binit.s的注释(The annotation of bootloader - 44binit).doc
- 腓骨弯曲骨折的X线诊断(The X-ray diagnosis of the fractured fibula fracture).doc
- 腐植酸钠(Humic acid sodium).doc
- 膨胀加强带(Expansion band).doc
- 财务管理系统资料(Financial management system information).doc
- 财富与就业联管理系的割裂(The division of wealth and employment is divided).doc
- 货架&超市货架(Shelves & supermarket shelves).doc
- 货车滚动轴承故障分析及防止方法(Truck rolling bearing failure analysis and prevention method).doc
- 货运车辆管理规定(Regulations on the management of freight vehicles).doc
- 货运检查员(Cargo inspector).doc
- 质量安全竞聘(Quality safety competition).doc
- 质量标语集锦质量标语集锦(Quality slogan collection of quality slogan).doc
- 质量管理标语(Quality management slogan).doc
- 购买水货手机验机注意事项(Pay attention to the inspection of water mobile phone).doc
文档评论(0)