日本原装进口高温一氧化碳气体传感器NAP-78A最高可耐200度
USERS MANUAL FOR NAP-78A
CATALYTIC TYPE INCOMPLETE COMBUSTION SENSOR
NEMOTOs NAP-78A is a newly developed catalytic type gas sensor designed to detect
incomplete combustion of domesticwater heaters to be installed indoors. Constant
monitoring of the combustion conditions of a water heater is possible by installing
an exclusively designed detecting unit with NAP-78A in a flue duct. When
incomplete combustion occurs, the unit will put out signals proportional to
incomplete combustion levels (CO gas concentration levels in a flue gas).
1. Applications
* FF type water heaters (Forced draught balanced Flue type)
* FE type water heaters (Forced Exhaust type)
* Water heaters for air conditioning
* Gas/Oil heaters
2. Features
* Temperature compensation is unnecessary in the wide range from room
temperature to 200oC.
* Depending on the kinds of fuel gases and their combustion conditions, the
ratio of H2 gas and CO gas generated upon incomplete combustion varies in
the range of 1:1 to 4:1 (CO:H ). However NAP-78A is applicable to almost
2
of all fuel gases because of its relatively low hydrogen gas dependency
characteristic.
* Excellent reproducibility and stability.
* Superior accuracy such as 300 ppm of CO gas in a flue gas can be detected.
* Small humidity dependency in a flue gas.
* Small-sized, lightweight, and less-expensive.
* Distinguished long term stability and durability.
* Easy calibration because of small individual differences in production lots.
* More than 10-year life was confirmed by accelerated tests using actual water
heating equipment.
* Excellent corrosion resistivity.