电缆工程工程量计算规则(Rules for calculation of quantities of cable engineering).doc

电缆工程工程量计算规则(Rules for calculation of quantities of cable engineering).doc

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
电缆工程工程量计算规则(Rules for calculation of quantities of cable engineering)

电缆工程工程量计算规则(Rules for calculation of quantities of cable engineering) Rules for the calculation of quantities of cable engineering -- (summary) 1. The excavation of the buried cable and the filling (stone) side, in addition to the special requirements, the earthwork can be calculated by the following table: - - Cable root width; -1~2- 0.45- Every additional one - 0.153- - two, the cable trench cover plate cover, the quota, according to each lid once to delay * meters. If it is uncovered and covered, it will be calculated two times. - Three, the cable protection tube * degrees, in addition to the provisions of the design * degrees, in case of the following circumstances, the following provisions shall be increased by the protection tube * degrees. - 1. cross the road, according to the width of the subgrade, plus 2m at each end. - 2. vertical installation, the pipe from the ground plus 2m. - 3., through the building exterior wall, according to the outer edge of the foundation plus 2m- 4. cross the drain and add 1m to the outer edge of the ditch. - Four, cable laying quota and its matching quota were not included in the material (also known as device materials), the other according to the design and calculation rules and regulations of the quota loss rate calculation material cost. - Five, cable protection pipe buried underground, the earthwork construction drawings indicate, according to the construction drawing calculation; no construction diagram according to the general and deep ditch 0.9m, groove width according to the protection of the outermost tube on both sides of the edge of the 0.3m working face calculation. - Six. Cable laying shall be calculated by single extension * meter. - Seven. Cabling shall be based on the laying of the horizontal and vertical of the laying path, plus additional * * * as specified in the table: - Item number - item * * * - Description - 1- cable sag, waveform curvature, cross 2.5%- * - cables according to calculation 2- cables enter

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档