化验所用仪器(Instrument used in laboratory).docVIP

化验所用仪器(Instrument used in laboratory).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
化验所用仪器(Instrument used in laboratory)

化验所用仪器(Instrument used in laboratory) Laboratory operating procedure for analytical balance 1, all new acquisition days should be measured by the verification average, issued a certificate before you can use. The balance shall be checked annually by the meter to ensure the accuracy of the balance. 2, the use of scales should be in accordance with the instructions required to operate, weighing before checking whether the balance is intact. 3, the use of the balance before the observation level in the air bubble is in the center of circular levels, such as off center, should be adjusted to keep the bubbles in the anchor bolt is the central level, single pan balance (Mechanical) anchor bolt to adjust the front of the anchor bolt behind electronic balance adjustment. 4, the balance shall be placed in such as silica gel desiccant, silica gel before use should observe the color, such as silica gel silica gel drying discoloration must be replaced in a timely manner, the failure of the water into the oven drying to restore the color of silica gel for later use. 5, the balance should be adjusted before use zero, electronic balance before use, but also the use of standard weights calibration. 6, in order to protect the balance of the knife edge, the use of a single plate balance should be half open, to be able to determine the weight of the weight of the so-called decimal point after the first digit, the weights will be accurate, and then completely open to read the exact value. 7 days, the exit switch moves to light, vibrations affect the accuracy of balance and accurate readings. 8, balance to balance the door shut, no open day exit reading, to prevent the air flow amount of the influence of symmetry. 9, the electronic balance of the peeling key should be used carefully, strictly prohibited to use the peeling key to make the balance back to zero. 10, if the balance of the tray on the dirt, immediately wipe clean. Balance should be often cleaned, keep clean, wipe the balance

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档