- 1、本文档共15页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
蓝光主板故障码(Blu ray motherboard fault code)
Detailed failure code analysis
ER2: open door interlock interrupt in elevator operation.
Phenomenon 1: during the operation, the door knife and the door collided with the door lock.
Phenomenon 2: if the FU16 is set to ON, the system determines whether the door lock is closed and the restriction signal of the door is concerned. If FU16 is set to ON, the unreliable stop limit will also cause ER03 protection.
Phenomenon 3: motherboard detection signal using two lock detection, X4 contact input, X23 lock loop voltage detection, such as lock loop voltage is not high enough, the requirements of the standard AC110V, such as lower than AC100V, the fault voltage input instability will cause ER02.
The phenomenon of 4:ER02 fault occurs on the top floor, synchronous traction machine, synchronous traction machine brake delay time is too long, easy to cause the lift onto the limit, this phenomenon, before the 02 emergency stop fault fault. (normal to the top floor parking, the system after the brake, so that the direction will remain set time, brake, off, time so that the elevator door is not closed stable, the inverter still has torque output. If the door lock is accidentally broken, the door lock contacts can turn off the frequency converter and cause the pulley limit.
Phenomenon 5: frequency conversion door machine, because the switch door signal from the control cabinet direct lead from the accompanying cable to the top of the car. Such as excessive interference during operation, the door controller receives the error error caused by open command, open the ER02 fault, which, in car top mounted on the opening and closing the relay control cabinet, first at the closing signal to drive the car top door to open and close the door by relay, relay contact control gate machine controller. The method can effectively prevent the signal from opening and closing the door to interfere with the misoperation of the door.
ER03: frequency converter tro
您可能关注的文档
- 艾伯伦异世界设定(Abbylan's different world settings).doc
- 艾滋病,你了解多少(How much do you know about AIDS).doc
- 蚌埠cgm灌浆料(Bengbu CGM grouting material).doc
- 苯与溴的取代反应(Substitution reaction of benzene with bromine).doc
- 避风港原则、红旗理论与百度文库(Safe haven principle, red flag theory and Baidu Library).doc
- 避孕药遭遇三大疑问(The pill faces three major questions).doc
- 辨正字音(Correct pronunciation).doc
- 辩论赛要点及技巧运用(Debating points and skills).doc
- 表面处理工艺技术(Surface treatment technology).doc
- 表面活性剂对pvc增塑糊稳定性能的影响及机理探讨(Effect of surfactant on the stability of PVC paste and its mechanism).doc
文档评论(0)