高层建筑结构设计(Structural design of high-rise building) 1. consider the concept of wind load on high-rise building, the following is true? The wind load is the main load of [A] high-rise buildings, the basic wind pressure value of W0 by the same multi-storey building, press 30 Once the maximum 10 minute mean wind pressure is determined; The wind vibration coefficient [B] of high-rise building, and the building stiffness are closely related, in general, the greater the stiffness of building. The wind vibration effect is greater; The calculation of wind vibration coefficient and wind pressure height coefficient [C] of high-rise buildings, should consider the influence of ground roughness; The following 2. high-rise buildings, calculation earthquake time history analysis method which should be used to supplement the calculation? [1] building fortification category B of high-rise buildings; [2] building fortification is a high-rise building; [3] high-rise building high soft; [4] the quality and stiffness along the vertical distribution of special non-uniform high-rise buildings. [A] [2] [4]; [B] [1] [3]; [C] [1] [2]; [D] [3] [4]; 3. the seismic design of high-rise buildings, more than the number of height combinations should be considered the effect of wind load and horizontal earthquake effect? [A] 40m; [B] 60m; [C] 80m; [D] 100m; [D] all high-rise buildings, should consider the wind vibration coefficient is greater than the influence of wind vibration 1. 4, high-rise building () play a major role in the structural analysis and design. A, B, vertical level C, D, the weight of the structure wind load 5, assuming a residential building, using cast-in-place reinforced concrete structure, the structure is 80 meters high, seismic intensity is 7 degrees, the most appropriate structural system. A, B, frame shear wall structure C, D, structure of cylinder frame tube structure 6, calculation framework of inertia moment I when considering the floor effect of cast-in-place slab, in the

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档