网站大量收购独家精品文档,联系QQ:2885784924

电气检修(Electrical overhaul).doc

  1. 1、本文档共30页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
电气检修(Electrical overhaul) preview First, fill in the blanks: 1. high voltage circuit breaker can not only cut off the high voltage circuit or closed (the no-load current) and (load current), and when a fault occurs, the (relay) role, cut off (load current) and (ISC). 2. load switch also has an obvious (disconnection point), there are certain (drying capacity), can (load) operation, but not directly disconnect (short-circuit current). 3. is prohibited in the only (circuit breaker) disconnect the power supply equipment; must be opened (switch), at least one obvious to all aspects (disconnection point). 4. neutral grounded system, called (grounded) system; neutral indirectly grounding power system, called (small current grounding system). 5. current transformer and relay wiring are commonly used (star), (incomplete star connection), (phase differential current connection, delta connection). 6. transformer oil in the transformer (insulation), play (ARC) and function (cooling). The 7. main transformer switch power supply and stop order operation, when the power to stop (the load side of the switch), stop (power sensor switch); power supply and the order (opposite). The 8. basic requirements of relay protection device is (selective), (fast), (sensitivity), (reliability). The 9. pole DC system grounding, can continue to (run), two case of grounding will cause the relay protection (mal). 10. in the substation two circuit diagram, YBM (warning signal) small bus symbols, the accident sound signal symbols for small bus (SYM). 11. in the circuit breaker control circuit, TWJ (tripping position relay) symbol, TBJ (anti jump relay) symbols. 12.SF6 is a kind of gas (colorless), (odorless), (non-toxic), non flammable (inert gas). 13. when the SF6 gas pressure inside SF6 breaker is lower than that of Mpa (0.4), a signal loop blocking signal, the prohibition of circuit breakers (SWITCHING) operation. 14. in the actual operation, the arc suppression coil should be avoided (compensation

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档