网站大量收购独家精品文档,联系QQ:2885784924

监理检查要点手机存放(Supervision check points mobile storage).doc

监理检查要点手机存放(Supervision check points mobile storage).doc

  1. 1、本文档共7页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
监理检查要点手机存放(Supervision check points mobile storage) Check the control points of construction process supervision To see the detailed drawings of all engineering supervision before the examination, especially the structure and other explanation 1, positioning line: check the positioning is consistent with the design and planning, to know the basic level point, elevation and Axis size check. 2, excavation: soil is consistent with the geological investigation report, whether the geological prospecting to the bearing layer, and the elevation axis The line size is consistent with the drawings, the surface is clean substrate, require drilling. 3, to witness the scene: uncoursed rubble masonry measurement, check the mix ratio of mortar, masonry first large stones to skin, face down, pressing each seam, mortar joint control in 3 centimeters, the width of each section of the Ministry of construction attention and height to consistent with the drawings, the actual amount of attention to the upper pressure lower uncoursed rubble masonry on foot note, ash plug tightly, when the upper masonry rubble rubble rubble when exposed to lower surface without mortar, masonry mortar check cannot be used instead of small stone packing, 600 wide hair stone to pull stones, see the specific set of specifications, the upper end of rubble masonry mortar height should not exceed 2 cm, if more than 2 cm, with leveling concrete. To make a hole site stone lintel, not large rubble lap. 4, independent foundation: check the basic control cap size drawing template section, reinforced to test qualified in the trial before the base steel banding the outer 2 bars to be tied to buckle, intermediate can be tied to plum buckle, attention regardless of the situation, the bottom length of the bars in the lower part of the bottom bar control drawings examination. Column load in the foundation reinforcement stirrup stable for at least 2, check the column model consistent with the drawings, pay attention to the b

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档