建筑消防工程竣工调试方案(Construction fire fighting project completion commissioning program) Completion of the building fire engineering commissioning scheme A, Project overview The fire control system commissioning is the main content: integrated debugging of automatic fire alarm and linkage system, water sprinkling system, hydrant system, gas fire extinguishing system, foam fire extinguishing system, smoke control system of fire and other fire fighting systems. Two, Engineering data check and test preparation 2.1 check data and on-site engineering equipment 2.1.1 fire hydrant system 2.1.1.1 fire hydrant box (including water, water and other accessories) should have the national fixed fire extinguishing systems and components of quality supervision and inspection center effective inspection report. 2.1.1.2 pump combination device should have the national fixed fire extinguishing systems and components of quality supervision and inspection center effective inspection report. 2.1.1.3 fire pump should have national fixed fire extinguishing systems and components of quality supervision and inspection center effective inspection report. 2.1.1.4 fire pump control cabinet should have fire 24V DC power supply to control the contact start stop action (action current is less than 1A); at the same time provide two sets of working state (starting state and stop state) passive contact. The fire pump control cabinet power supply should be mutual investment with a dual power supply. 2.1.1.5 fire pressure tank should have a national fixed fire extinguishing systems and components of quality supervision and inspection center effective inspection report. 2.1.2 smoke control system 2.1.2.1 exhaust valve, fire valve should have a national fixed fire extinguishing systems and components of quality supervision and inspection center effective inspection report. 2.1.2.2 exhaust fan, positive pressure fan should have national fixed fire extinguishing systems and components of quality supervision and

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档