- 1、本文档共8页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
发电机(Alternator)
1 Introduction
Xishui power plant 4 * 135MW generator, Shanghai Turbine Generator Co. production QFS50 300MW series dual internal water cooled turbo generator, model QFS - 135 - 2, respectively in September 2001, January 2002, July 2002, October 2002 grid. No. 4 machine had Water Leakage generator fault shutdown event after stop check Water Leakage reasons for stator cooling water pipes due to blockage of the superheater tube to. After the unit maintenance, found the other 3 units of the stator clamping ring cooling pipe blocking phenomenon also exist in different degrees, timely dredge treatment, to avoid similar accident.
No. 24 generator Water Leakage fault phenomenon and check processing
In July 21, 2008 14:30, an alarm generator No. 4 leak detector, on-site inspection found the generator body with water spray, reduce the cold water pressure generator in the regulation is invalid, check the downtime for fault (before the stoppage of the unit load 80MW, power factor 0.95, generator coil temperature, core temperature and air cooling, water cooling system parameters of normal). After exposing the development of motor end cover check, Water Leakage reasons for the exciter end of generator stator cooling water pipe to pipe explosion.
Check the situation as follows:
The cooling water pipe leak in the inner loop of the stator inner pressure ring, from 50 to 600 at the top of the generator.
The cooling water pipe is at a slight bulge, the paint off phenomenon near the drain.
The cooling water through the compressed air from the inlet side access check, compressed air, compressed air leakage and leakage of compressed air from the outlet end access, no leakage of compressed air leakage. Reflect the cooling water outlet to the point (lower half circle) block.
The opening check out of the water in the corner end leakage of cooling water pipe, water inlet pipe without debris, the inner wall of pipe is natural, the outlet pipe with black soft sediment.
Check t
您可能关注的文档
- 护理心理学(Nursing psychology).doc
- 湖北2010年自考宝石琢型设计及加工课程考试大纲(Hubei 2010 self-taught gem cutting design and processing course examination outline).doc
- 湖北黄石资源枯竭背后企业多有恋矿情结(Hubei Huangshi resources exhausted enterprises have love complex).doc
- 护士礼仪(Nurse etiquette).doc
- 护士面试题(Interview questions for nurses).doc
- 护士面试题目(Interview questions for nurses).doc
- 护士题(Nurse question).doc
- 护士题5(Nurse questions 5).doc
- 护士心理(Nurse psychology).doc
- 护士资格(Nurse qualification).doc
- 春季运动会广播稿(A broadcast of the spring games).doc
- 春季运动会加油稿大全(The spring games!).doc
- 春节服装促销方案(Spring Festival Clothing promotion program).doc
- 发动机12.9级连杆螺栓的材料与工艺(Material and process of engine 12.9 stage connecting rod bolt).doc
- 春甜桔栽培技术汇编(Compilation of spring sweet orange cultivation techniques).doc
- 春晚剧组还没找我(I haven't seen me at the Spring Festival Gala).doc
- 发动机过热的诊断与排除(Diagnosis and removal of engine overheating).doc
- 春之声(Voice of spring).doc
- 地下管理方面(Underground management).doc
- 搭配法(Collocation method).doc
文档评论(0)