继电保护课程设计(Course design of relay protection).docVIP

继电保护课程设计(Course design of relay protection).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
继电保护课程设计(Course design of relay protection)

继电保护课程设计(Course design of relay protection) The first chapter: the original data of 1 The network connection section 1.1 as shown in Figure 1-1 1 Section 1.2 network parameters 2 Section 1.3 design content 2 The second chapter designs the content of 3 The parameters of Section 2.1 computing network 3 Section 2.2 of the protection operation mode 6 Section 2.3 to calculate the maximum short-circuit current, short-circuit current calculation and Ik of each section of the road 6 Protection of Section 2.4 lines to identify 7 The third chapter design experience 16 Reference 17 The first chapter of the original data Section 1.1 of the network connection as shown in Figure 1-1 Figure 1-1 110kV single power ring network wiring diagram Section 1.2 network parameters (1) each line in the network using current and voltage protection with or without direction, the transformer longitudinal differential protection as the main protection. The transformer is Y/ -11 connection?. (2) the maximum generating capacity of power plant (2 * 25+50) minimum generating capacity of 2 MW, 25 MW X. (3) the normal operation of the network is the largest power plant generating capacity and closed loop operation. (4) allow the fault clearing time of 0.85 seconds. (5) 110 thousand volt switch adopts DW2 - 110 type, trip time it is 0.05 ~ 0.08 seconds. (6) the maximum load current line of AB, BC, AD, CD, 150A and 230A were 230A and 140A, since the start of the load coefficient was Kss=1.5. (7) as the action time of each substation outgoing line backup protection, backup protection t=0.5s?. (8) the reactance of the line is 0.4 euro / km. The voltage transformer is 110000/100. Other parameters such as shown in Figure 1 - 1. Section 1.3 design content (1) to determine the protection circuit breaker 2, 4, 6 and 8 phase fault; (2) short circuit calculation and sensitivity check protection; (3) the principle diagram of circuit breaker protection device to draw 4 and start map, and a list of equipment list;

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档