浅谈消防水泵接合器的设置问题(Set on fire pump adapter).docVIP

浅谈消防水泵接合器的设置问题(Set on fire pump adapter).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
浅谈消防水泵接合器的设置问题(Set on fire pump adapter)

浅谈消防水泵接合器的设置问题(Set on fire pump adapter) Set on fire pump adapter Abstract: according to the provisions of the fire pump adapter design specification, this paper elaborates and discusses the water pump adapter in fire protection system set requirements, partition settings and fire water booster, and fire water quantity and the distance, the relationship between the outdoor fire hydrant specific design methods and practices. Keywords: fire, water pump adapter, fire pump, outdoor fire hydrant, fire water tank, booster facilities Fire pump adapter with fire protection system to connect the interior with a fire truck or pump motor. Fire truck or pump motor through the pump adapter interface, send the fire water to buildings or other liquid fire extinguishing agent, to extinguish fire inside the building, solve the high-rise building or other building in case of fire, the indoor fire pump inside the building due to the maintenance, power outages, failure or indoor water supply pipe at low pressure. The problem of water shortage or not water supply. In our country, fire pump adapter is set as a temporary water supply facilities, water supply to the fire pump is added in water. Different pipeline pump adapter of different uses of the connection point. Here with us to discuss about some problems of pump adapter settings. 1, the layout of fire pump combination device: According to the specification and related reference materials and the author participated in the project, the fire pump combination device layout is summarized as follows: (1) fire pump combination device should be arranged outdoors; (2) as far as possible the use of ground type, and should be clearly marked signs; (3) fire pump adapter the site should be located in the fire truck, does not impede traffic; (4) wall adapter and the building should have a certain distance, generally not less than 5m; (5) according to the requirements of the fire pump adapter, and outdoor pool fire hydrant or distance should be 1

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档