design and analysis of a 24 vdc to 48 vdc bidirectional dc-dc converter specifically for a distributed energy application设计和分析的24伏直流电48 vdc双向直流-直流转换器专门为分布式能源的应用程序.pdfVIP

design and analysis of a 24 vdc to 48 vdc bidirectional dc-dc converter specifically for a distributed energy application设计和分析的24伏直流电48 vdc双向直流-直流转换器专门为分布式能源的应用程序.pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
design and analysis of a 24 vdc to 48 vdc bidirectional dc-dc converter specifically for a distributed energy application设计和分析的24伏直流电48 vdc双向直流-直流转换器专门为分布式能源的应用程序

Energy and Power Engineering, 2012, 4, 315-323 /10.4236/epe.2012.45041 Published Online September 2012 (http://www.SciRP.org/journal/epe) Design and Analysis of a 24 Vdc to 48 Vdc Bidirectional DC-DC Converter Specifically for a Distributed Energy Application 1 2 Ambrosio B. Cultura II , Ziyad M. Salameh 1Mindanao University of Science and Technology, Cagayan de Oro City, Philippines 2University of Massachusetts Lowell, Lowell, USA Email: acultura2003@, ziyadsalameh@ Received July 19, 2012; revised August 20, 2012; accepted August 31, 2012 ABSTRACT The design of a bidirectional DC-DC power converter specifically for a distributed energy application is presented. The existing two different DC voltage battery bank of the distributed generation needs to interlink each other using a bi-directional DC-DC converter in order to minimize the unbalance of the output load currents of the three inverters connected to electric grid system. Through this connection, a current can flow from one system to another or vice versa depending on which systems need the current most. Thus, unbalanced currents of the grid line have been minimized and the reliability and performance of the DER grid connected system has been increased. A detailed mathematical analysis of the converter under steady state and transient condition are presented. Mathematical models for boost and buck modes are being derived and the Simulink model is constructed in order to simulate the system. Moreover, the model has been validated on the actual operation of the converter, showing that the

您可能关注的文档

文档评论(0)

xyz118 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档