初入结构工程(Initial entry structural engineering)

初入结构工程(Initial entry structural engineering) Structural design has been the way from zero ?????????????? A =M/ (gamma f h) gamma beam for general approximate to 0.875, on board the approximate combination design of 0.9M for the need to balance the pull beam moment and pull beam bearing in the vertical load on the bottom of the column moment value to bar based on a strip foundation can be divided into three categories: strip foundation mixed column strip foundation, strip foundation, concrete wall and column wall under (commonly used frame shear wall structure) and strip foundation under wall plate shear checking delta root section to determine the root thickness of strip foundation design is the bottom points of single column base meter close to delta the square of the two-way force bearing capacity, need to check, the punching force; strip foundation is a strip-shaped member of unidirectional stress, need to check the shear stress. The bottom foundation of strip foundation under strip foundation width delta = delta wall do not need to set up a secret base beam delta root thickness hand calculation: accurate calculation of floor root thickness, by concrete shear control is less than 0.7 * V * f * b * h beta 2: a base (empirical estimation net) 1/6~1/4 simplified algorithm in the half width of strip foundation under wall reinforcement reinforcement mainly considering the influence of bending moment?? the root bending moment is the largest section of the base plate control: M=p a /2 (a for the net pick span)?? after the calculated bending moment can be obtained reinforced by the following equation???????? A =M/ (0.9f h)?? provisions of regulations, per meter distribution reinforcement area not less than the reinforced area of the 1/10 delta when the base width is greater than or equal to 2500mm, in order to save 0.9 times, reinforced length width the staggered arrangement, single Sole foundation also has this request. The column strip foundation column between the bas

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档