工作接地与保护接零的区别与计算(Difference and calculation between work grounding and protection zero connection).doc

工作接地与保护接零的区别与计算(Difference and calculation between work grounding and protection zero connection).doc

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
工作接地与保护接零的区别与计算(Difference and calculation between work grounding and protection zero connection)

工作接地与保护接零的区别与计算(Difference and calculation between work grounding and protection zero connection) Difference and calculation between work grounding and protection zero connection.Txt This article is contributed by ADDZB DOC documents may experience poor browsing on the WAP side. It is recommended that you first select TXT, or download the source file to the local view. Work earthing and protection zero connection First, the grounding is now widely used in the summer of three and four wire power supply system, the neutral point of transformer is directly grounded, the ground called ground work. From the distribution transformer (or generator) of the neutral point line called the line (or zero). The three-phase voltage between three line four wire end is 220 volts, called phase voltage for lighting or power. Why small single-phase neutral point three-phase four line supply system generally connected with earth? It is this: (a) can be quickly cut off the fault equipment. In ungrounded power generation system, a phase grounding, grounding current is very small, not enough to make the protection device to removal of faulty equipment. In the neutral point of power system directly grounded in single-phase grounding, will cause a large single-phase grounding current protection device can make rapid action, cut In addition to equipment fault. (two) reduce the electric voltage of human body is exposed. In neutral grounded system, when a person is, and on another, the human body with the voltage is 380 volts line voltage. But the system of neutral point grounding, when people the body touch phase, with the voltage of 220 volts. (three) to reduce the power line and the insulation level of electrical equipment to reduce the cost. In the neutral grounding system, each the voltage is the voltage, so the power line of the system and according to the phase voltage to design. The insulation level of the metal shell or the conductive parts of electrical equipment to reduce the cost. B

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档