a piezoelectric plethysmograph sensor based on a pt wire implanted lead lanthanum zirconate titanate bulk ceramic压电传感器体积描记器基于pt线植入钛酸铅锆酸镧陶瓷.pdfVIP

a piezoelectric plethysmograph sensor based on a pt wire implanted lead lanthanum zirconate titanate bulk ceramic压电传感器体积描记器基于pt线植入钛酸铅锆酸镧陶瓷.pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
a piezoelectric plethysmograph sensor based on a pt wire implanted lead lanthanum zirconate titanate bulk ceramic压电传感器体积描记器基于pt线植入钛酸铅锆酸镧陶瓷

Sensors 2010, 10, 7146-7156; doi:10.3390/s100807146 OPEN ACCESS sensors ISSN 1424-8220 /journal/sensors Article A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic Carlos O. González-Morán, J.J. Agustín Flores-Cuautle and Ernesto Suaste-Gómez * Centro de Investigación y de Estudios Avanzados del IPN, Electrical Engineering Department, Bioelectronics Section. Av. IPN 2508, Col. San Pedro Zacatenco, C.P. 07360, México D.F., Mexico; E-Mails: cgonle@cinvestav.mx (C.O.G.-M.); jjflores@cinvestav.mx (J.J.A.F.-C.) * Author to whom correspondence should be addressed; E-Mail: esuaste@cinvestav.mx; Tel.: 52-55 Fax: 52-55 Received: 15 June 2010; in revised form: 30 June 2010 / Accepted: 15 July 2010 / Published: 29 July 2010 Abstract: This work reports on the development of a Lead Lanthanum Zirconate Titanate (PLZT) bulk ferroelectric poled ceramic structure as a Piezoelectric Plethysmograph (PZPG) sensor. The ceramic was implanted during its fabrication with a platinum (Pt) wire which works as an internal electrode. The ceramic was then submitted to an experimental setup in order to validate and determine the Pt-wire mechanical effects. This PZPG sensor was also mounted on a finger splint in order to measure the blood flow that results from the pulsations of blood occurring with each heartbeat. Fingertip pulses were recorded jointly with an ECG signal from a 25 year old male to compare the time shift; the PZPG sensor guarantees the

您可能关注的文档

文档评论(0)

118zhuanqian + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档