预压托换桩加固及顶升纠偏工地进程实践

3 7 18.69.15 mm/d 3 d 0.530.007 7 mm/d5 a TU 472.2 A 1000 6915(2005)15 2795 07 FOUNDATION REINFORCEMENT AND BUILDING RECTIFICATION OF DEVIATION BY JACK-UP AND PRELOADING UNDERPINNING PILE Abstract A 3-story brick concrete structural building was added to 7-story in Xi′an CityShaanxi Provinceand the new-added part is a frame structure. Because two different structural systems are not separated completely and the designer adopted unsuitable ground treatment method the building became leaning seriously when the major structure was completed. The inclination ratio and settlement rate of building are up to 18.6 and 9.15 mm per dayrespectively and the building is bound to collapse. The scheme of rectifying deviation by jack-up and by preloading underpinning pile was employed after investigation for sake of safety. Based on this case the following aspects are investigated the formula to determine the numbers of underpinning piles for rectifying leaning building is presented scheme choice of rectifying deviationdesigning methodconstruction procedure of preloading underpinning pile jacking monitoring and controlling are introduced in derail difficult factors and corresponding problems during jacking construction are provided. After 3-day jack-up constructionthe inclination ratio of building is steady at 0.53 and settlement rate is less than 0.007 7 mm per day and tends to be stable. After five years regular service it can be concluded that preloading underpinning pile is feasible to reinforce or rectify similar structures and project in loess

文档评论(0)

ctuorn0371 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档