通力无机房电梯故障代码(Failure code of KONE elevator without engine room)
通力无机房电梯故障代码(Failure code of KONE elevator without engine room)
Failure code of KONE elevator without engine room
Code fault name, cause, status, operation
0001 driving time is long, the position signal 30/B30 has not changed after a running time, immediately stop the switch, 0003 speeding for:v2lcedrv
0004 three consecutive failures of synchronous operation, three consecutive simultaneous operation, the system can not correctly receive the deceleration level signal, after three failures, stop at the end of the station power off
0007 door switch 308030 clamping, start a period of time, did not detect the falling edge of the 30/B30 signal, the door area switch 30/B30 has been effectively running to the target floor, the door does not take the car, power off or maintenance
0008NVRAM damage or capacity is insufficient. When power is transmitted, the capacity of NVRAM is not enough to replace NVRAM
The 0014 gate check circuit does not release the 486.443; the 1.443:2 either runs 2 consecutive times (ACO/ACL) to the destination floor, leaving the service switched off
The 0015 gate check circuit has no pull in 486.443; the 1.443:2 either runs 2 times continuously (ACO/ACL) to the destination floor, leaving the service off
0021 、 the safety circuit is blocked, the safety circuit is input 1, no voltage is stopped immediately, the safety circuit is switched on or in the state of electric operation.
0022 hall door lock, safety loop, enter 3, no voltage, stop the door lock immediately
0023, the car door lock is not safe, enter 2 no voltage, stop the car door lock immediately
0025 start system failure, elevator stop, the main contactor is not released, do not start the main contactor troubleshooting
0026 drive system fault drive system fault is detected (v3FCK lamp) does not start off electric or maintenance, or a thermal switch transistor v3f16es tachometer fault 0027 K7 relay to failure by physical damage caused by the relay itself or the K7 pull. The main contactor does not p
您可能关注的文档
- 贺姓起源(The origin of his surname).doc
- 贺普仁效穴整理(He Puren hole finishing).doc
- 贾康个税改管理革应通过抽肥补瘦培育中等阶层(Jia Kang tax change management leather should be through fat, thin, cultivate medium class).doc
- 贾谊治安策(一)(Jia Yi peace policy (I)).doc
- 贺普仁效穴(He Puren effect point).doc
- 资料 孔雀东南飞百年研究综述(A review of a hundred years' research on Peacock Flying Southeast).doc
- 资料分析(Data analysis).doc
- 资料四有效的作业设计(Data four effective job design).doc
- 资本与技术(Capital and technology).doc
- 资本主义制度的确立与发展(The establishment and development of capitalist system).doc
- 基础化工行业新疆煤化工正当其时,关注产业链三大投资方向.docx
- 汇纳科技动态报告:实控人拟变更,开启AI生态新布局.docx
- 黄金坑成功兑现:后续是高低结构再平衡.docx
- 华峰铝业首次覆盖报告:夯实优势领地,弄潮新蓝海.docx
- 华达科技合资时代冲压龙头,卡位新能源增厚业绩.docx
- 金融信息服务行业用户积累与ARPU提升决定金融信息服务企业盈利能力.docx
- 金融工程动态跟踪:高质量改革方案出炉,今年公募新发产品规模破3400亿.docx
- 金融工程:大模型总结和解读行业研报.docx
- 健全约束与引导机制,推动公募高质量发展.docx
- 建筑材料行业深度报告:2024年年报及2025年一季报综述,需求继续承压,行业竞争出现缓和信号.docx
文档评论(0)