空调检查(Air condition check)

空调检查(Air condition check) 1, low pressure, high pressure, low, replace the compressor. 2, double pressure to exhaust, or heat problems. 3, surface shaking system has water vapor, evacuation must be more thorough. 4, pressure double low loss refrigerant, otherwise the system is closed. Following a detailed analysis about the meaning of the formula: 1, when the use of air conditioning pressure gauge detection, air-conditioning system low pressure than normal high, and high pressure is lower than normal, at this time, air conditioning refrigeration can not achieve the effect of normal air conditioning. General failure is due to wear in the air-conditioning pump, resulting in power decline. This time, often need to replace the compressor to solve the problem 2, when the system of high and low are higher than normal, control formulas, common fault systems are generally air or adding an excess refrigerant, this time need to vacuum, then add the right amount of refrigerant can solve the problem. But there is a situation that cooling is bad, especially when the ambient temperature is relatively high, often lead to more severe heat, the failure reason is the general heat sink plug, dirt, fan speed is not enough and so on. 3, when the air conditioning system work, if the pressure hands shook, that there is water system. To solve this problem, you usually need to re vacuum, the pumping time must be no less than 15 minutes, when necessary, also need to replace the drying bottle, in order to thoroughly remove the moisture in the system. 4, when the high and low pressure are low, there are two possibilities: one is system congestion, system congestion, the plug will produce throttling, throttling parts will have obvious temperature difference, with the hand feel can find the problem. Another possibility is that refrigerant leaks, which lead to insufficient refrigerant, are common, when an air conditioning tester must be used to identify leaks or replace or repair them. The air co

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档