1, over flow
Overcurrent is the most frequent phenomenon of frequency converter alarm.
1.1 phenomena
(1) when restarting, a speed is tripped. This is a very serious overcurrent phenomenon. The main reasons are: load short-circuit, mechanical parts are stuck, the inverter module damage, motor torque is too small and so on.
(2) power on the jump, this phenomenon can not generally reset, the main reasons are: the module is broken, the drive circuit is bad, the current detection circuit is bad.
(3) when restarting, it does not trip immediately, but in acceleration, the main reasons are as follows: the setting time of acceleration is too short, the setting of current limit is too small, and the torque compensation (V/F) is higher.
1.2 example
(1) a LG-IS3-43.7kW converter starts and jumps on OC
Analysis and maintenance: open the hood found no signs of any damage, online measurement of IGBT (7MBR25NF-120) the basic judgment is no problem, in order to further determine the problem, the power transistor 7 measurement unit IGBT remove after the opening and the closing are very good. When measuring the drive circuit of the half bridge, it is found that there is a distinct difference between the circuit and the other two paths. After careful examination, it is found that an optocoupler A3120 output pin is short circuited with the power supply negative pole. After the replacement, the three circuits are basically the same. The module is loaded with electricity and works well.
(2) a BELTRO-VERT2.2kW frequency converter will jump on OC and cannot be reset.
Analysis and maintenance: first check the inverter module and find no problems. Then check the driving circuit and no abnormal phenomenon, not in this one estimation problem may be in the current signal processing of this part, the sensor circuit removed after power on, that everything is normal, so that the
您可能关注的文档
- 扳手腕训练文档(Wrench wrist training document).doc
- 批处理的极限应用(Limit application of batch processing).doc
- 找回好睡眠(Get a good sleep).doc
- 找回还原精灵的密码的七种方法(Seven ways to retrieve the restore wizard's password).doc
- 找回丢失的windows 任务栏图标(Retrieve the missing windows taskbar icon).doc
- 找工作的五险一金你懂么(The job five social insurance and one housing fund you know).doc
- 找广告牌上的错别字大全(Find the billboard typos Daquan).doc
- 批处理bat文件实现各种功能(Batch bat file implements various functions).doc
- 找回删除的文件 __一不小心把文(Recover deleted files __ accidentally put a paper).doc
- 技击之神李书文(Li Shuwen, the God of martial arts).doc
文档评论(0)