排除变频器软故障的方法(Method for eliminating soft fault of frequency converter).doc

排除变频器软故障的方法(Method for eliminating soft fault of frequency converter).doc

  1. 1、本文档共4页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
排除变频器软故障的方法(Method for eliminating soft fault of frequency converter)

排除变频器软故障的方法(Method for eliminating soft fault of frequency converter) Method for eliminating soft fault of converter.Txt 1, over flow Overcurrent is the most frequent phenomenon of frequency converter alarm. 1.1 phenomena (1) when restarting, a speed is tripped. This is a very serious overcurrent phenomenon. The main reasons are: load short-circuit, mechanical parts are stuck, the inverter module damage, motor torque is too small and so on. (2) power on the jump, this phenomenon can not generally reset, the main reasons are: the module is broken, the drive circuit is bad, the current detection circuit is bad. (3) when restarting, it does not trip immediately, but in acceleration, the main reasons are as follows: the setting time of acceleration is too short, the setting of current limit is too small, and the torque compensation (V/F) is higher. 1.2 example (1) a LG-IS3-43.7kW converter starts and jumps on OC Analysis and maintenance: open the hood found no signs of any damage, online measurement of IGBT (7MBR25NF-120) the basic judgment is no problem, in order to further determine the problem, the power transistor 7 measurement unit IGBT remove after the opening and the closing are very good. When measuring the drive circuit of the half bridge, it is found that there is a distinct difference between the circuit and the other two paths. After careful examination, it is found that an optocoupler A3120 output pin is short circuited with the power supply negative pole. After the replacement, the three circuits are basically the same. The module is loaded with electricity and works well. (2) a BELTRO-VERT2.2kW frequency converter will jump on OC and cannot be reset. Analysis and maintenance: first check the inverter module and find no problems. Then check the driving circuit and no abnormal phenomenon, not in this one estimation problem may be in the current signal processing of this part, the sensor circuit removed after power on, that everything is normal, so that the

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档