爱默生机房空调故障现象及处理办法(Air conditioning malfunction in Emersons computer room and its treatment).docVIP

爱默生机房空调故障现象及处理办法(Air conditioning malfunction in Emersons computer room and its treatment).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
爱默生机房空调故障现象及处理办法(Air conditioning malfunction in Emersons computer room and its treatment)

爱默生机房空调故障现象及处理办法(Air conditioning malfunction in Emersons computer room and its treatment) Air conditioning malfunction in Emersons computer room and its treatment Unit has a Emerson room air conditioning, from the Internet saw this article, feel useful, special pick to spare. I. air duct system failure The air duct system comprises a fan, an air filter screen and two micro pressure differential controllers. When the filter dirty alarm when the differential pressure at the bottom of the controller can screw clockwise to eliminate the alarm, counterclockwise in a circle. Of course, such as after adjustment still can not eliminate the alarm, then show that the filter has been dirty to a certain extent, need to be replaced. The fan will automatically stop the transfer after three minutes when the air condition alarm appears. The reason for the malfunction of air duct is that: 1, fan motor failure, so that fan stop; 2, fan belt after long-term wear and tear, the fan motor is actually idling; 3 、 there is obstruction in the duct of the air pressure differential gauge; 4, the filter is too dirty, so that the resistance of the air duct system becomes larger; 5, fan over-current protection off, cause AC contactor release; 6, 24V transformer problems or output terminal is not firm and loose; 7 、 the air duct pressure gauge is not adjusted properly; 8, the motor side pulley loose failure; Air duct troubleshooting: 1, measuring fan motor three-phase static resistance should be the same, grounding resistance should be above 5M; 2, the replacement of the motor belt, check the belt tension, belt tightness should be moderate, with the thumb thumb press about 10mm better; 3. Clear the pressure gauge to detect foreign objects in the pipe; 4. Replace the air filter. 5. The fan over-current protector is reset manually, and the fan current is measured. (reset should be in place) 6. Check the input and output voltage of 24V transformer and fasten the connection points. 7. Re adjust the

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档