2009年全国电子设计大赛题目(2009 National Electronic Design Contest).doc

2009年全国电子设计大赛题目(2009 National Electronic Design Contest).doc

  1. 1、本文档共17页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
2009年全国电子设计大赛题目(2009 National Electronic Design Contest)

2009年全国电子设计大赛题目(2009 National Electronic Design Contest) Photovoltaic grid connected power generation simulator (A title) [undergraduate group] I. task A photovoltaic grid connected power generation simulator is designed and fabricated, and its block diagram is shown in figure 1. Simulation of photovoltaic battery, DC regulated power supply for US and US=60V RS=30 ~36 resistance RS, Omega omega; sinusoidal reference signal into analog voltage uREF, the frequency of peak 2V, fREF for 45Hz~55Hz; T frequency isolation transformer, ratio of n2:n1=2:1 and n3:n1=1:10, the feedback signal uF as the output current of the load resistance; RL=30. ~36. Two, requirements 1. basic requirements (1) with maximum power point tracking (MPPT) function: RS and RL within a given range of changes, so that the relative deviation of the absolute value is not greater than 1%. (2) with frequency tracking function: when fREF changes within a given range, the frequency of uF is fF=fREF, and the absolute value of relative deviation is not greater than 1%. (3) when RS=RL=30, DC-AC converter efficiency higher than 60%. (4) when RS=RL=30, the distortion of the output voltage is less than or equal to 5% THD uo. (5) has input undervoltage protection function, action voltage Ud (th) = (25 + 0.5) V. (6) have output over-current protection function, action current Io (th) = (1.5 + 0.2) A. 2. play part (1) to improve the efficiency of DC-AC converter, which is more than 80% (RS=RL=30 ohm). (2) to reduce the distortion of the output voltage of the THD is less than or equal to 1% (omega, RS=RL=30). (3) the implementation of phase tracking function: when the fREF changes in a given range and non resistance load, uF and uREF can guarantee the in-phase, the absolute value of the phase error is smaller than 5 deg. (4) after the overcurrent and undervoltage faults are eliminated, the device can be automatically restored to its normal state. (5) other. Three, description 1. all communication in this subject is

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档