开机吹扫方案(Startup purge scheme)

开机吹扫方案(Startup purge scheme) 25600m3/h unit Driving, heating, purging plan Start the circulating water pump and air compressor only, and carry out heating and purging on the air separation unit circulating water system 1. air conditioning compressor cooling water backwater valve, regulating the circulating water pump outlet valve and total return valve, the air compressor cooling water flow control is more than 1200m3/h, the total water supply pressure is 330kpa, the total return pressure 210kpa, the total water cycle of more than 2500m3/h. Get ready before driving 1. cooling water inlet and outlet valve is fully open, the interstage cooler is used, the water side is exhausted, the oil level is normal, the oil cooler is used, the oil side and the water side exhaust. 2. start the air compressor auxiliary oil pump, adjust the oil temperature, oil pressure. 3. the instrument gas is fully restored and confirmed that the vanes and emptying valves are in normal operation, and the DCS logic and interlocking adjustment are completed 4. molecular sieve valve check switch location, debugging normal 5. all air blowing valves on the air separation tower are closed and all valves of the system are closed 6. molecular sieve system: turn on V1203, all other valves are closed (molecular sieve is suspended, 1# is running, 2# is heated for 68 minutes) 7. check the air compressor control logic, to meet the boot conditions 8. prepare a flow chart for the heating purge mark 9. electrical professionals confirm that the grid allows for the start of the air compressor 10. professional equipment arranged from V241, V242 valve Start the air compressor 1. check all starting conditions of air compressor: (1) the entrance of a guide vane opening closed (2) two level entrance gateopening closed (3) the vent valve V1046 is fully open; (4) normal oil temperature is greater than 20 degrees centigrade (5) after normal oil pressure (greater than 2.3Bar) 60S; (6) starting interval time (20 minutes) to

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档