建筑弱电工程师习题(Building weak engineer problem)
建筑弱电工程师习题(Building weak engineer problem)
First, individual choice questions
1, Chinas intelligent building design standards that year promulgated (C).
A, 1984 B, 1994 C, 2000 D, 2002
2, building automation system referred to as (C).
A, FAS, B, CAS, C, BAS, D, SAS
3, automatic detection technology, which is the detection of non electric energy into electricity detection (D).
A, power factor B, voltage C, current D, speed
4, the intelligent building site controller adopts computer technology, also known as direct digital controller, referred to as (B)
A, DVD, B, DDC, C, DSP, D, DCE
5, the control function is dispersed, and the operation management is centralized, so it is called decentralized control system, referred to as distributed control system, and its English alphabet is (A)
A, DCS, B, DCE, C, DCP, D, DSS
6 、 in the building automation control system, the widely used executing agency is (C)
A, pneumatic actuator B, hydraulic actuator C, electric actuator D, hybrid actuator
7, cold ice machine outlet water temperature is generally (B)
A, 00C, B, 70C, C, 120C, D, 200C
8 、 independent coil control with three speed switch temperature control (C)
A, 200C to 250C, B, 00C to 250C, C, 50C to 300C, D, 50C to 250C
9. The DC operating voltage of the fire fighting linkage equipment shall comply with the GB156 regulations, and priority shall be adopted (C)
A, AC18V, B, DC18V, C, DC24V, D, AC24V
10 、 the DC equipment of fire fighting linkage equipment should send out the linkage control signal within (B) time after receiving the fire alarm signal.
A, 1S, B, 3S, C, 1min, D, 10min
11, automatic alarm button and the location of fire hydrants shall not exceed in each fire district (C)
A, 10M, B, 15M, C, 30M, D, 35M
12, the intrusion detector has a strong anti-interference ability, and for the beam axis (C) or greater than any of the external light source interference signal, should not produce false positives.
A, 5 degrees B, 10 degrees C, 15 degrees D, 20 degrees
13, as the tr
您可能关注的文档
- 就李昌奎案与车浩博士再商榷(Discuss Dr. Li Changkui's case with Dr. Hao Hao).doc
- 就业指导考试部分问题答案(Part of the questions about the employment guidance test).doc
- 尼龙(nylon).doc
- 局域网ping不通原因(Lan Ping blocked reason).doc
- 局域网ping不通的原因(The reason why Lan Ping is blocked).doc
- 尚丰五步棋打造金牌营销团队(Shang Feng five moves to create the gold marketing team).doc
- 局域网不能访问共享问题(LAN does not access shared problems).doc
- 尼龙简介及特性(Introduction and characteristics of nylon).doc
- 尽显华夏风景教你风光摄影拍摄技巧(Show Chinese scenery, teach you scenery photography skills).doc
- 局域网共享问题全方位解决(LAN sharing problem, a comprehensive solution).doc
原创力文档


文档评论(0)