汽轮机详细设计方案书参数
7.0.0
a) STEAM TURBINE
Maximum continuous rating of turbine (MCR)
汽轮机
汽轮机最大连续蒸发量 MW 150 MW at generator terminals
在发电机接线头为150MW b) Generation during valve wide open (VWO) condition
阀门全开时的出力 MW + 5% on TMCR Generator terminals
高于TMCR工况5% c) Live steam pressure at turbine inlet
汽轮机入口流通蒸汽压力 bar(a) By Bidder
由投标人填写 d) Live steam temperature at turbine inlet
汽轮机入口流通蒸汽温度 By Bidder
由投标人填写 e) Hot reheat temperature at turbine inlet
汽轮机入口再热热段温度 By Bidder
由投标人填写 f) Permissible deviations of live steam pressure and live steam temperature
流通蒸汽压力和温度的允许偏差 - According to IEC Recommendations, (The latest edition.)
按照IEC标准(最新版本) g) Cooling water temperature at condenser inlet
冷凝器入口处的冷却水温度 33 h) Temperature rise of cooling water in condenser at TMCR of turbine
当TMCR工况下冷却水在冷凝器中的温升 10 i) Maximum cooling water velocity in condenser tubes with 10% blocked tubes
10%堵塞情况下凝汽器管中的最小冷却水速率 m/s 2.2 j) Minimum cooling water velocity in condenser tubes
凝汽器管中的最小冷却水速率 m/s according to requirement of sponge ball equipment
按照胶球设备的必要条件 k) Speed of turbine rotor
汽轮机转子转速 rpm 3000 l) Frequency deviations at Maximum Continuous Rating
最大连续出力时的频率偏移 47.5 Hz to 51.5 Hz Sr. No. 8.0 Description Condenser
冷凝器描述 Unit Data
数据 Type
类型 Horizontal Surface type divided water box construction with single or two pass design, integral air cooling section and steam inlet at the top or side.
Surface area
表面面积 10% over above the designed surface area
超过设计表面积的或10% Temperature rise
温升 oC 10 oC Design Heat Load
设计热负荷 Turbine VWO with 3% make-up and normal condenser vacuum.
Head Loss through condenser
通过冷凝器的压头损失 6 m WC
6m水柱的压力 CW velocity
冷却水流速 1.6 m/s to 2.2 m/s
1.6 m/s to到2.2 m/s Max. oxygen in condensate
冷凝器内最大含氧量 0.015 cc per litre for 50% to 100% unit load and 0.03cc per litre for loads below 50%
50% 100%机组负荷时每公升含0.015 cc,机组负荷低于50%时每公升含0.03cc Cooling water temperature at inlet
进口冷却水温度 33 deg C Max. Cooling water temperature at inlet (design)
36 deg C Cooling media
冷却介质 Clari