“节能领跑者”冰箱理论分析与实验验证研究
陈开松 魏邦福 尚殿波 王冬祥
(合肥美菱股份有限公司,230601)
*
摘 要 本文以一款 BCD-248W 三门风冷无霜冰箱为研究载体,为达到“节能领跑者”冰箱
的能效指数要求(“节能领跑者”冰箱的能效指数定为22% ),从理论分析与实验验证两方面
分析几种节能技术的可行性。结果表明,通过冰箱变频控制规则优化 ,CFD 软件模拟风道
结构优化 ,高效保温材料VIP 板的合理布置应用 ,高效压缩机的应用等方案可将冰箱能效
指数约为29.4% (能耗为0.58kWh/24h )降低至能效指数为22% (能耗为0.43kWh/24h ),
能耗降低达25.2% ,达到“节能领跑者”冰箱的能效指数要求。
关键词 节能 无霜冰箱 变频控制 CFD
Theoretical Analysis and Experimental Research on Refrigerator
Called“ Energy Saving Leader ”
Chen Kaisong Wei Bangfu Shang Dianbo Wang Dongxiang
( Hefei Meiling Co.,Ltd.,230601 )
Abstract In order to achieve the energy efficiency index (the energy efficiency index is set to
22% )for the refrigerator called“ energy saving leader ” ,the feasibility of several energy saving
technologies is verified by theoretical analysis and experiment based on the refrigerator called
*
BCD-248W with three door and no frost. The results show that the energy efficiency index is
reduced from 29.4% (energy consumption of refrigerator is 0.58 kWh/24h) to 22% (energy
consumption of refrigerator is 0.43 kWh/24h) by some solutions with variable frequency 、CFD
software simulation for duct structure design、the reasonable layout of VIP in refrigerator 、high
efficiency compressor and so on, the energy consumption of refrigerator is reduced by 25.2%, and
achieve the energy efficiency index requirement of the refrigerator called “energy-saving leader”.
Key words Energy saving No frost refrigerator Control with variable frequency CFD
[1]
发电技术 ;另一方面是在提供能源利用
0 前言
效率上下功夫,积极寻求提能效降能耗的
随着人类社会的发展,全球正面临能 方案,实际上提高能源利用效率比开发新
源短缺
您可能关注的文档
最近下载
- 江苏省靖江市2024-2025学年七年级上学期1月期末道德与法治试题(含答案).docx VIP
- 城市轨道交通线路与站场课件 模块三:城市轨道交通线路平面.pptx VIP
- KONE通力电梯501系统扶梯调试技术介绍.ppt
- 长假节后收心会.pptx VIP
- 10kV线路设计架空线.doc VIP
- 2025年全国双高计划学校建设名单及专业群名称.pdf VIP
- Q/GDW 11222-2014 配电网低励磁阻抗变压器接地保护装置技术规范.pdf VIP
- 炎德英才大联考长郡中学2025 届高三月考试卷(六)语文.docx VIP
- 基层医疗机构常见病诊疗手册(全科医生版).docx VIP
- GB_T 11351—2017《铸件重量公差》国家标准解读.pdf VIP
原创力文档

文档评论(0)