英文版 网架设计说明及施工要求
Project Overview
Project name
Project site
Project scale (space frame projected area) see pic
Project structure:
Orthogonal?spatial?square pyramid?grid?with bolt-sphere?joints?
Space frame support mode: Bottom chord column support
Space frame plan size and rise: see it in the plan and elevation of the space frame
Roof system
Safety level: second level
Usage: 50 years
Design Overview
1. This project adopts SFCAD2006 FOR WINDOWS software to auxiliary design.
2. Design principles of space frame: external?load of space frame made the load
concentrate in the joints according to the static?equivalent?principle. Pls ignore the
effect of the joint stiffness when you calculate and suppose joints are hinged joint and
member bars only bear axial force. We adopt space truss displacement method when
we design.
3. Control stress of member bar: f≤185N/mm2
4. Control limit of member bar’s slenderness ratio: compression?bar ?≤180 tie bar ?≤180
5. Deflection control of space frame: w≤L/250
Basis of design, construction and quality?evaluation
Architectural?structure?load?standards (GB50009-2012)
Earthquake Resistant Design Code (GB50011-2010)
Space frame structure technology procedures(JGJ7-2010)
Steel structure design standards(GB50017-2003)
Structural reliability design standard(GB50068-2001)
Cold-formed thin-walled steel structure technical specifications(GB50018-2002)
Roof?Construction?Technology?Code(GB50345-2004)
Steel structure construction quality acceptance code(GB50205-2001)
Space frame nodes with high strength bolts(GB/T16939-1997)
Steel space frame bolt-sphere?joints(JG/T10-2009)
This project’s technical files and relevant documents
System loads( not contain the space frame’s self-weight)
Dead load of top chord: 0.20KN/m2
Dead load of bottom chord: 0.20KN/m2
Live load of roof: 0.50KN/m2
Wind load:0.30KN/M2
Snow load:1.30KN/M2
Seismic fortification: 9℃
7. Temperature:±40℃
space frame materials
Steel tube: it adopts Q235B steel. Apply to the “Space