JIS C 9335-1∶ 2003与IEC60335-1∶2001的差异
JIS C 9335-1: 2003与IEC60335-1:2001的差异:
Class 0 appliance is accepted only for indoor type appliance of which rated voltage is less than 150V.
8.1.1
Regarding electrical lamp holder, the following requirements shall be confirmed:
When lamp holder E14 is charged during insertion of its lamp cap, the lamp holder shall be constructed so that the live parts can not be contacted.
For lamp holders E11, E12, E17, E26 and E39, when each lamp cap has been completely inserted,
the lamp holder shall be constructed so that the live parts can not be touched.
The verdict shall be given as follows:
-For lamp holders E11, E12, E17, E26 and E39, the standard test finger B shown in figure 1 is applied, and according to the purpose of test, the manufacturer of lamp holders shall provide electric bulbs to meet with the testing lamp holders.
- For lamp holder E14, the gauge in line with the current version of standard sheet (7006-31) of IEC 60061-3 shall be used.
The test pin 13 is applied without appreciable force through openings in Class 0 appliances, Class II appliance or Class II constructions, except for those giving access to lamp caps and the live parts of socket-outlets and connectors of cord-sets.
An accessible part is not considered to be live if
-the part is supplied at safety extra-low voltage, or for Class 0 appliances, power from insulating transformer conformed to withstand voltage test of reinforced insulation of 16.3 provided that:
for a.c. the peak value of the voltage does not exceed 42.4 V;
for d.c. the voltage does not exceed 42.4 V;
10.1
Limit deviation tolerance of rated input for PTC device as heating element is ± 15% regardless of its rated value.
11 table 3:
Replacement of footnote f:
The temperature rise has to be determined in order that the tests of Clause 30.1 can be carried out.
Materials for which temperature limits are not specified in the table, but which comply with the requirements as shown in Attachment 1 are considered to be acceptable.