MPS – Vacuum System Interface Requirements.doc

  1. 1、本文档共3页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
MPS – Vacuum System Interface Requirements

MPS – Vacuum System Interface Requirements (WBS 1.4.2.4, WBS 1.5.5) The Vacuum system should turn off the beam under two conditions: (1) a beamline vacuum valve is closed due to poor vacuum, operator command, or system failure, and (2) if the vacuum conditions in a particular beam line sector are out of the acceptable running limits. The vacuum system inputs to the Machine Protection System (MPS) will use the Beam Permit Inputs. These inputs latch in the OFF state until an operator resets the condition. It might be desirable to have the vacuum inputs from the Cavities go into the Fast Protect System where the inputs are reset automatically the next pulse, or as soon as the input is satisfied. This would impact the grouping of signals in the super conducting linac. Vacuum system inputs to the MPS may be combined as long as the conditions causing the valve to close are logged and the devices that are combined do not cross a Machine running mode boundary. The Machine Protection System will mask out inputs from devices not required for a particular machine running mode. The machine running modes are as follows: Front End – All devices from the source to the end of the MEBT. Linac Dump - All devices in the, DTL, CCL, SRF, and HEBT to the Linac Dump, Devices after HEBT:DH1 in the HEBT are excluded. Injection Dump – All devices after and including HEBT:DH1 in the HEBT, devices in the injection straight section of the ring, and devices in the injection dump line. Ring – All devices in the ring except Injection straight section, Lambertson, and extraction kickers. Extraction Dump – Lambertons and extraction kickers, RTBT devices up to RTBT:DH13, and devices in the EDMP line. Target – All devices after RTBT:DH13. Figure 1. Beamline Modes Vacuum – MPS Fault Condition Requirements Fail Safe – Any inputs to the MPS should be fail safe, if the system providing the input goes out of service, is rebooted, etc. the MPS input should go into the fault state. If an IOC is used

文档评论(0)

qiwqpu54 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档