Experimental determination of section sensitivity profiles and image noise
in electron beam computed tomographya
Cynthia H. McCollough,b) Kalpana M. Kanal, Nicholas Lannutti, and Kelly J. Ryan
Department of Diagnostic Radiology, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905
Received 9 September 1998; accepted for publication 3 December 1998
To determine the effect of continuous-volume scanning CVS on z-axis resolution, section sensi-
tivity profiles were measured on an electron beam computed tomography CT scanner and com-
pared with those obtained using the step-volume scanning SVS mode. A steel bead was imaged
using different scan parameters, and the mean CT number over the bead was plotted against the
z-axis position to determine section sensitivity profiles. From these profiles, full width at half
maximum FWHM, full width at tenth maximum FWTM, and full width at tenth area FWTA
were calculated. A uniform water phantom was imaged to measure noise. To determine the visual
significance of changes in the section sensitivity profile, a section thickness and contiguity phantom
was imaged. All section sensitivity profiles measured had an FWHM value within 0.5 mm of the
nominal scan width. The FWTM and FWTA values increased with the CVS mode compared with
the SVS mode. This broadening of the section sensitivity profiles was most significant with larger
collimator widths. However, use of smaller collimator widths increased image noise. When all other
parameters remained constant, increasing the exposure time to reduce image noise did not affect the
section sensitivity profile. The CVS mode produced wider section sensitivity profiles than the SVS
mode. This effect was minimized when the smallest collimator width was used, but at the expense
您可能关注的文档
- Potential and Perspectives of Cyclonucleosides英文文献.pdf
- Improved phase only correlation method for low quality fingerprint matching英文文献.pdf
- ON2 log2N Filtered Backprojection Reconstruction Algorithm for Tomography英文文献.pdf
- Impact of enhanced geothermal systems on US energy supply in the twenty first century英文文献.pdf
- WIND TUNNEL MODELLING OF CONVECTION OF HEAT BETWEEN AIR AND BROAD LEAVES OF PLANTS英文文献.pdf
- Sequence Analysis of Chromatin Immunoprecipitation Data for Transcription Factors英文文献.pdf
- A scheme for multisource interior tomography英文文献.pdf
- Argonaute proteins key players in RNA silencing英文文献.pdf
- Web Search Results Clustering Based on a Novel Suffix Tree Structure英文文献.pdf
- Robust Estimation of Ultrasound Pulses Using Outlier Resistant De Noising英文文献.pdf
- An integrated view of molecular coevolution in protein protein interactions英文文献.pdf
- Use of Stem Cell Radiation Chimeras to Analyze How Domains of Specific Proteins Impact on Murine NK Cell Development In Vivo英文文献.pdf
- High Speed Communication Circuits and Systems Low Noise Amplifiers英文文献.pdf
- Highly Ordered Arrays of Metal Semiconductor Core Shell Nanoparticles with Tunable Nanostructure英文文献.pdf
- The economics of harvesting predator prey systems英文文献.pdf
- The primary factors which determine the microstructures of pyrolytic carbons deposited in a tumbling bed英文文献.pdf
- Systems Integration and Architecting An Overview of Principles, Practices, and Perspectives英文文献.pdf
- Optimal harvesting policy for an age specific population英文文献.pdf
- Reducible Polyoligo d arginine for Enhanced Gene Expression in Mouse Lung by Intratracheal Injection英文文献.pdf
- SUMO E3 ligase activity of TRIM proteins英文文献.pdf
文档评论(0)