Multimode扫描探针显微镜仪器及原理

SPM Fundamentals for the MultiMode 1 Control Mechanisms and Feedback: 2 Feedback and Gains 3 Control Parameters and Feedback 4 Hardware Review of tapping mode AFM 5 1. Hardware The MultiMode SPM consists of seven components: SPM, controller, computer, keyboard, mouse, display monitor and control monitor. The central component of the system is the SPM. Main components: SPM Head Scanners Probe holders Probes 1.1 SPM Head Illustrates an MM-SPM head with various adjustment knobs. The head and attached X-Y stage are kinematically mated to the scanner via three contact points. A pair of retaining springs secure the head, allowing it to be raised and lowered using adjustment screws threaded through the scanner body. This picture shows the arrangement of the photodiode elements in the MultiMode head. The top two elements (A) and the two bottom elements (B) provides a measure of the vertical deflection of the cantilever. The two left photodiodes (C) and the two right photodiodes (D) provides a measure of the torsional deflection of the cantilever. 1.2 Scanners Figure shows some scanners which are used for different sample. Smaller scanners tend to be more noise-free. Larger offer wider scans, while requ- iring extra noise dampening precautions at smaller scan sizes of high resolution. Note:1.All scanners are interchangeable. 2. When a scanner is changed, the parameter file for the new scanner must also be changed. Figure 2.1f depicts the electrode configuration used on a typical scanner piezo tube. AC voltages applied to the scanner crystal X-Y axes produce a raster-type scan motion represented in Figure 2.1g. The sample and mode of SPM to be performed dictate the choice of probe and probeholder. Probe holders might also be referred to as “tip” or “cantilever” holder. “probe holder” is the preferred nomenclature 1.3.Probe holders 1.4 Probes Probes come in a variety of sizes, shapes and materials and are chosen according to the type of imaging being

文档评论(0)

xy88118 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档