GE系列PDU原理文档.doc

  1. 1、本文档共23页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
GE系列PDU原理文档

Last Revised: December 2004 This module contains the following sections: Section 1 - Overview Section 2 - NGPDU Physical Description Section 3 - NGPDU Service Overview Section 4 - NGPDU Electrical Specifications Section 5 - NGPDU Drawings Section 6 - NGPDU LEDs Section 7 - NGPDU Control Board Switches and Fuses 1??Overview The PDU provides a single location to connect input power for the entire CT system. Its function is to provide the following features to the System: Compensation means for a wide range of input voltages via tap selection Provide required system AC power from a single source Provide High Voltage DC power for x-ray generation Provide power for gantry axial rotation Provide a means for emergency shutdown of all x-ray and drives power circuits Provide system AC power circuit protection Provide an interface for an external UPS connection Meet the requirements of IEC601 for both radiated and conducted emissions The PDU is designed to comply with United States Federal Regulations and the European Medical Device Directive. It bears the certification marks of a United States National Recognized Test Laboratory with Canadian deviation or a Canadian certified test house. Each unit is identified as being in compliance by being labeled with the official mark(s) of each respective agency. While in the stand-by mode, the NGPDU does not generate sound levels in excess of 50dbA, when measured at a distance of one meter from the nearest cabinet surface, in any direction. 2??NGPDU Physical Description 2.1??Mechanical Enclosure The enclosure has a front, rear and top access covers. The top cover is installed on the frame with a captive fastener in the middle of front edge. The front cover weighs less than 22 lbs (10 kg). A single full-width Lexan safety shield is provided under the front cover. It extends ?” below the top front edge of the assembly to the bottom of all HVDC Supply components, including the PDU Control Board. The rear cover is held in place by two

文档评论(0)

xcs88858 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8130065136000003

1亿VIP精品文档

相关文档