Operations Manual for NEMA TS2 and 2070 Controllers;一、基本操作;相位基本参数;;;;;流量密度模式 (volume density mode);;Added Initial is set to 1” . “times per actuation” (T/Ac) is set initially to the Minimum Green. T/Ac is extended by 2 vehicle calls each adding 1” of Added Initial to the T/Ac timer. ;Time Before Reduction (TBR), Cars Before Reduction (CBR) After the TBR or CBR delay expires, the initial Gap,extension will be reduced to the Min Gap value over the Time to Reduce (TTR) period specified. The ;The Dynamic Max Limit and Max1 or Max2 provide an upper and lower limit to the phase max time. If a ph