按摩器EMC要求

EMC Declaration (Continued) Guidance and manufacturer’s declaration – electromagnetic immunity The XXX” is intended for use in the electromagnetic environment specified below. The customer or the user of the “XXX” should ensure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance ?6 kV contact ?8 kV air ?6 kV contact ?8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Electrostatic discharge (ESD) IEC 61000-4-2 ?2 kV for power supply lines ?1 kV for input/output lines ?2 kV for power supply lines ?1 kV for input/output lines Mains power quality should be that of a typical commercial or hospital environment. Electrical fast transient/burst IEC 61000-4-4 ?1 kV differential mode ?2 kV common mode ?1 kV differential mode ?2 kV common mode Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 5 % UT (95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles 5 % UT (95 % dip in UT) for 5 sec 5 % UT (95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles 5 % UT (95 % dip in UT) for 5 sec Mains power quality should be that of a typical commercial or hospital environment. If the user of the “XXX” requires continued operation during power mains interruptions, it is recommended that the “XXX” be powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 3 A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE UT is the a.c. mains voltage prior to application of the test

文档评论(0)

xy88118 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档