下颈椎前路椎弓根螺钉固定系统的有限元建模及研究-finite element modeling and research of anterior pedicle screw fixation system for lower cervical spine.docx

下颈椎前路椎弓根螺钉固定系统的有限元建模及研究-finite element modeling and research of anterior pedicle screw fixation system for lower cervical spine.docx

  1. 1、本文档共44页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
下颈椎前路椎弓根螺钉固定系统的有限元建模及研究-finite element modeling and research of anterior pedicle screw fixation system for lower cervical spine

万方数据 万方数据 下颈椎前路椎弓螺钉固定系统的有限元建模及分析 3-dimensional finite-element study on anterior transpedicular screw fixation system of the subaxial cervical spine Abstract Objective Using 3-dimensional finite-element analysis to compare the biomechanical properties of models reconstructed by the anterior cervical pedicle screw fixation system (Anterior Cervical Transpedicular Screw, ACTPS) and the cervical anterior screw plate system (Anterior Cervical Locked-plate, ACLP) after 2 levels corpectomy, and provide a theoretical evidence for clinical application. Methods CT data (C 1-T 1) was collected from a 28 years old male volunteer.The 3- dimensional nonlinear subaxial cervical (C3-C7) intact model was established and analyzed by Mimics 11.0, Rapidform XOR3, Hypermesh10.0, CATIA5V19, ANSYS 14.0 softwares. The axial force of 75N and moment couple of 1N·m was loaded on the upper surface of C3, made the model movement in flexion extension, lateral bending, rotating direction,respectively .Then,recorded the range of motion (ROM) ,and compared the results with the in vitro biomechanical experimental data of Panjabi and Moroney. ACTPS and ACLP internal fixation model were established .The ROM of the two models were calculated by ANSYS software. The Von Mises stress distribution and maximum stress value of ACTPS group and ACLP group were recorded and analyzed ,to compare the ROM of the two internal fixation models with intact model. Results There were 85,832 elements and 23,612 nodes in the intact model of subaxial cervical spine (C3-C7) be established in this experiment, and the ROM of intact model validated with the reported cadaveric experimental data of Panjabi and Moroney. In ACTPS model group, the stress was been well-distributed relatively, but in ACLP model group, the stress concentrated on the interface between screw and the titanium plate. There were obvious differences of the maximum stress value of the two groups. The ROM of ACTPS group of fixed segments was smaller than ACL

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档