椎弓根螺钉植入近红外实时监测技术基础分析-basic analysis of near infrared real - time monitoring technology for pedicle screw implantation.docxVIP

椎弓根螺钉植入近红外实时监测技术基础分析-basic analysis of near infrared real - time monitoring technology for pedicle screw implantation.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
椎弓根螺钉植入近红外实时监测技术基础分析-basic analysis of near infrared real - time monitoring technology for pedicle screw implantation

南京航天航天大学硕士学位论文 摘 要 椎弓根螺钉内固定是脊柱外科的常用手术,目前存在植偏、误植等问题,对钉道偏差缺乏 直观有效的监测手段。本文提出了一种基于近红外光谱技术的椎弓根螺钉植入监测技术,对提 高椎弓根螺钉内固定手术植钉的准确性与安全性具有重要意义。 论文围绕近红外椎弓根螺钉植入监测技术的算法原理、监测系统设计与实现以及验证性实 验等方面进行研究。主要研究内容包括:1、提出了一种组织光学参数的漫反射率反演算法并通 过实验对算法准确性验证;2、搭建了一套近红外椎弓根螺钉植入监测系统,能够实时监测植钉 过程中钉道前方组织约化散射系数( μs′ )的变化;3、通过动物实验研究发现椎弓根钉穿刺钉道 上的组织 μs′ 与组织结构存在密切关联,并研究了正常穿刺钉道与内偏植钉钉道上的 μs′ 随深度 的变化规律;4、通过人尸体实验证实 μs′ 可作为反映植钉穿刺钉道偏差的识别因子,并得到了 植钉穿刺钉道上的 μs′ 安全阈值,将来可将此阈值作为开发植钉导航报警设备的参考依据。 论文主要创新点:(1) 首次将近红外光谱技术用于椎弓根螺钉植入手术的钉道监测;(2) 探 索并通过实验证明了约化散射系数( μs′ )可以作为钉道导航的识别因子;(3) 获得了穿刺钉道上 的 μs′ 随深度的变化规律及人体植钉穿刺钉道上的 μs′ 安全阈值。 关键词:近红外光谱、植入监测、约化散射系数、椎弓根螺钉、钉道 I 椎弓根螺钉植入近红外实时监测技术基础研究 椎弓根螺钉植入近红外实时监测技术基础研究 II II ABSTRACT Currently pedicle screw fixation is a common spinal surgery and exist some problems such as perforation deviation and incorrect implantation. Since lacking intuitive and effective monitoring methods during clinical pedicle screw fixation surgery, a real-time monitoring technique for pedicle screw fixation based on NIRs was brought to improve the accuracy and safety of screw implantation. This study mainly focuses on the simulation and implementation of algorithm principle, the design and implementation of monitoring system and validatable experiments revolving this monitoring technique.The aspects mainly include as follows: (1) Develop a kind of optical properties retrieval algorithm based on the diffuse reflectance and verify the accuracy of the algorithm through experiments;(2) Implement a set of NIRs monitoring system for pedicle screw planting which can measure the reduced scattering coefficient( μs′ ) ahead of screw path during the surgery;(3) Animal experiments verify that the reduced scattering coefficient of tissue in screw path is closely associated with tissue structure of screw path. Meanwhile we have discussed the reduced scattering coefficient variation of the normal puncture and internal perforation; (4) Adult cadaver experiments verify that the reduced scattering coefficient is the identifying factor t

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档