多端直流输电系统线路保护研究-电力系统及其自动化专业论文.docxVIP

多端直流输电系统线路保护研究-电力系统及其自动化专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
多端直流输电系统线路保护研究-电力系统及其自动化专业论文

Subject : The Research on Protection of MTDC Specialty : Power System and Automation Name :Zhang Ruoya (Signature) Instructor :Fu Zhouxing (Signature) ABSTRACT Compared with the double-ended HVDC systems, multi-terminal DC system has advantages in large-capacity and long-distance transmission of power and work in a more flexible and economical way. For DC line, fast and reliable operation of relay protection is critical to maintain stability of HVDC system. Currently the principle of travelling wave protection provided by the ABB company and the SIEMENS company is used as the main protection. And differential protection, under-voltage differential protection, low voltage protection are used as the backup protection. Due to the theoretical defects of various protection principles at present, it is indispensable to study new protection methods to accomplish the line protection in a better way. A parallel type of four multi-terminal DC system is built in PSCAD based on the analysis of the control mode, principle and topological structure of parallel multi-terminal DC system in this paper. Considering the requirement of real-time of line protection algorithm and the detection of fault transient signal effectively, an improved recursive wavelet algorithm is used to extract the quantity of fault transient signals under specific frequency, which only uses historical data to calculate with the advantages of a small amount of calculation and fast speed. Failure criterion is constructed according to the difference of fault signal high frequency component based on the filtering unit when external or internal fault occurs. And fault pole identification is implemented according to the difference changing direction of current when external or internal fault occurs. When the two conditions above meets at the same time, line protection acts. The validation of the algorithm is carried on using MATLAB. Simulation results show that the protection with the IRWT algorithm, which i

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档