大型多分支水轮发电机故障及异常工况仿真研究-电力系统及其自动化专业论文.docx

大型多分支水轮发电机故障及异常工况仿真研究-电力系统及其自动化专业论文.docx

  1. 1、本文档共69页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
大型多分支水轮发电机故障及异常工况仿真研究-电力系统及其自动化专业论文

II II Abstract The research on multi-branch hydro generator transient simulation mainly concentrates to the study of the internal faults simulation research at present, because the comprehensive internal faults simulation research is the base of the quantitative design generator main protection scheme. But for now, there is not enough research about the fault of branch shutdown and rotor eccentricity. So it?s difficult to make sure whether the main protection scheme can sensitively detect the branch shutdown fault and whether the protection would take malfunction, when an abnormal operation eccentricity happened to the generator rotor, which can be accepted in the process of generator running. This paper mainly studied the fault of branch shutdown and rotor eccentricity through digital simulation method, after which discussed the main protection scheme for the fault of branch shutdown and the influence of rotor eccentricity to the generators normal condition . When the fault of branch shutdown occurs in multi-branch generator, the phase currents and voltages will not change violently. So it is very difficult to identify the fault. On the basis of engineering practice and the generator internal fault transient simulation model which is established on stator single-turn coil and equivalent damp loops, establishes a generator branch shutdown simulation model on the HYPERLINK /dict_result.aspx?searchword=%e8%80%83%e8%99%91amp;tjType=sentenceamp;style consideration of the change of the practical HYPERLINK /dict_result.aspx?searchword=%e8%be%b9%e7%95%8camp;tjType=sentenceamp;style boundary . After studying on the changes of the basic electric quantity under the fault of branch shutdown occurs in generator on the right bank station of the Three Gorges, this paper analyzes the characteristics of generator main protection considering the actual Setting Value of generator main protection of the Three Gorges, and points out that the zero-sequence transverse differential prot

文档评论(0)

peili2018 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档