网站大量收购闲置独家精品文档,联系QQ:2885784924

低辐射剂量低碘对比剂负荷下兔脑CT灌注成像的可行性研究-影像医学与核医学专业论文.docx

低辐射剂量低碘对比剂负荷下兔脑CT灌注成像的可行性研究-影像医学与核医学专业论文.docx

  1. 1、本文档共36页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
低辐射剂量低碘对比剂负荷下兔脑CT灌注成像的可行性研究-影像医学与核医学专业论文

II II 中文摘要 低辐射剂量低对比剂负荷下兔脑 CT 灌注成像的可行性研究 结果:三组方案所得兔脑 CT 灌注成像伪彩图均显示满意。三组方案测得脑 CBF 平均值分别为(44.94±7.74)、(43.98±9.43)、(44.27±1.54)ml/(min·100g)。CBV 平均 值分别为(2.02±0.45)、(2.16±0.52)、(2.16±0.37) ml/100g,MTT 平均值分别为 (3.45±1.09)、(3.39±0.87)、(3.56±1.17)s,三组方案各灌注参数之间差异无统计学 意义。三组扫描增强峰值时大脑中动脉 CT 值分别为(439.83±37.86)、(421.33±30.58)、 (408.67±23.89)HU,SNR 值分别为(17.89±5.89)、(16.59±4.71)、(17.08±3.77),差异无 统计学意义。 结论:低浓度低剂量碘对比剂条件下的兔脑 CT 灌注成像,可降低碘负荷,而对 灌注参数结果及图像质量无明显影响。 关键词:碘对比剂;低浓度;低剂量;体层摄影术,X-线计算机;兔脑灌注成像 作 者:闻 芳 指导教师:胡春洪 PAGE PAGE IV 低辐射剂量低对比剂负荷下兔脑 CT 灌注成像的可行性研究 英文摘要 CT perfusion imaging of rabbit brain with low radiation dose and low contrast agent load in the feasibility study Abstract Part I CT Perfusion imaging of rabbit brain with 70 kV tube voltage in the feasibility study Objective: To evaluate the feasibility of low dose CT perfusion imaging of brain. Materials and Methods: Twenty New Zealand white rabbits underwent cerebral CT perfusion imaging twice with tube voltage 70 kV and tube voltage 80 kV, and the check interval is 24 h. The effective dosage (E)、cerebral perfusion parameters (CBF、CBV、MTT) and image quality indicator (SNR) of middle cerebral artery of each protocol were acquired and compared statistically. Results: The effective dosage of 70 kV group and 80 kV group were 1.91 and 2.93 mSv, the effective dosage of 70 kV group reduced for 34.8% as compared with that of 80 kV. There were no significant differences between the cerebral perfusion parameters acquired at different corresponding ROI. SNR of 70 kV group and 80 kV group were (23.15±5.98) and (21.23±9.18), there were not significant. Conclusion: The effective dosage of 70 kV cerebral CT perfusion imaging could be dramatically reduced and the results of perfusion parameters and image quality were about the same. Key words: Low dose; Tomography, X-ray computed; Rabbit brain perfusion imaging; Effective dosage 英文摘要 低辐射剂量低对比剂负荷下兔脑 CT 灌注成像的可行性研究 Part Ⅱ CT Perfusion imaging of rabbit brain with low concentration

文档评论(0)

peili2018 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档