基于igbt器件的pwm整流器异常高次谐波问题与解决方案-电子与通信工程专业论文.docxVIP

基于igbt器件的pwm整流器异常高次谐波问题与解决方案-电子与通信工程专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
基于igbt器件的pwm整流器异常高次谐波问题与解决方案-电子与通信工程专业论文

AbstractAbstract Abstract Abstract With the usage of high power,impu]sion,and un]inear loads in iron and steel manufacturers,complexity of these manufacturers’power distribution network,and 1 imi tations of environment protection and production costs,power distribution systems of iron and steel manufacturers get working under the critioal condition more and more.Then it makes the operation condition more unpredictable.And the safety and stabilization become important factors of iron and steel manufacturers’safe production.In recent years,the requirements of power economy and resource protection make the application of high voltage rectifier more and more common.The application of high—speed fully controllable power electronic transducer such as IGBT enhances the upper 1imit of harmoniC disturbance in iron and steel power distribution network from 1250 Hz to about 5000 Hz.And tbiS results the normal analyzed methodⅢand resolvent of harmonic can’t answer to the requirements of power distribution systems operating safely and stably with high frequency harmonic. So to build new theory of harmonic analysiS,especially model of simulink computation of high harmonic becomes the urgent affair to settle the safe and stable operation problems of those manufacturers. Through the analysi S of abnormal high frequency harmonic of 10 kV HB bus bar distribution system in Baosteel(Thi S paper agrees on the above wave of 2500 Hz to be called the abnormal harmonic),thiS paper summarizes the transverse(between point to poi nt)and lengthways(between high voltage to low voltage)transmission characters and calculation methods of current and vol rage of abnormal harmonic:points out the importance of capacitance parameter of electric cable in network impedance computation and Simulink computation:and sets up the calculation methods 摘要of 摘要 of distribution cables’capacitance at high frequency,based on testing datum,and methods to buil d and modify Simulink modelS:then creates the technique

您可能关注的文档

文档评论(0)

131****9843 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档